RMS Technologies R356-RO CONTROLLER/DRIVER User Manual

Page 7

Advertising
background image

must first be set up to work with the encoder by understanding the CPR and

calculating an encoder ratio. See the Appendix of this user manual.
Default Settings

Function (command)

Description

Running Current (m)

25% of 3.0 Amps

Holding Current (h)

10% of the run current

Step Resolution (j)

256x

Top Velocity (V)

305175 pps (microsteps/sec)

Acceleration (L)

L=1000, 6103500 μsteps/sec

2

Position

0

Microstep smoothness (o)

1500

Outputs (J)

Both are turned off, J0, inputs 1 & 2

Baud Rate

9600 bps

Table 1: Default Settings

2. ELECTRICAL SPECIFICATIONS

Supply Voltage:

+12 to +40 VDC

Peak Current:

0.3 to 3.0 Amps

Digital I/O Specifications

Number of I/O

4

Number of Inputs

2

Input Voltage

+0 VDC to +5 VDC

(0 to 24V tolerant, but 5V recommended)

Input Current

700 mA

Pull-up Resistors

20k Ω

Protection

Static Protection to the microprocessor

For a 1.8° stepper:
Steps per Revolution: 400, 800, 1600, 3200, 6400, 12800, 25600, 51200

3. OPERATING SPECIFICATIONS

Maximum Step Frequency

2^24 (pps) or 16.7MHz

Operating Temperature Range

0° to 50° C

Storage Temperature Range

-20° to 70° C

Communication Specifications
Interface Type

RS485 (RS232 or USB with a converter card)

Baud Rate

9600*, 19200, or 38400 bps

# Bits per character

8 Data

Parity

None

Stop Bit

1

Flow Control

None

*default

R356 Controller & Driver

Page 7

Version 1.01

RMS Technologies

4/3/2009