RMS Technologies R356-RO CONTROLLER/DRIVER User Manual

Page 21

Advertising
background image

LED or other output

The two I/O lines, pins 2 & 10, can drive an external device such as solenoids, LED’s,
or switches. The bidirectional I/O’s are switches to ground internally, and therefore

need to be connected to the +V of the power supply. Below is a recommended
connection for lighting an LED with 20 mAmps:

Upon entering command /1J0R, both pins 2 & 10 will output 1 Amps. The 1.2k ohm
resistor will limit the current to 20 mAmps into the LED. Select any ohm value to

limit your current based on the device that is connected to the output. I/O’s are
24VDC tolerant.

Optical Sensor

Figure 11: Opto Sensor Connection Schematic

Use the following table to solder the corresponding wires.

Optical Sensor

DB15 Cable

Pin #

Green 

Green/white

12

Black 

Green/white

12

Red 

Yellow/white

6

White 

Orange/white

7

Table 8

R356 Controller & Driver

Page 21

Version 1.01

RMS Technologies

4/3/2009

Advertising