5 emergency handwheel operation, 9 maintenance and care, 10 disassembly – Festo Неполноповоротные приводы Sypar DAPS User Manual

Page 4: 11 troubleshooting

Advertising
background image

1

2

3 4

5

1 Lock nut with sealing ring

2 Threaded rod

3 Piston

4 Port 2 (A)

5 Port 4 (B)

Fig. 12

1. Vent the DAPS and close the process valve. The pistons run to the inside end

position, as a result of spring return, until the spring disc is held, if necessary, by
the threaded rod. This fixes the threaded rod – dependent on the current set-
ting. Loosening of the lock nut will then not accidentally change the current
setting.

2. Screw down the lock nut with sealing ring. If the threaded rod has loosened,

retighten it by hand until a light resistance is felt.

3. Supply compressed air and open the process valve. The pistons move to the

outer end position.

4. Adjust the end position:

Observe that a complete turn of the threaded rod can change the swivel angle
approx. 1.5° to 3.5° – dependent on the product design.
– Turning the threaded rod clockwise increases the spring travel.
– Turning the threaded rod anti-clockwise reduces the spring travel.

5. Vent the DAPS and close the process valve. The pistons are moved to the inside

end position, as a result of spring force, until the threaded rod and the spring
disc delimit the spring travel.

6. Check the position of the process valve. To change the swivel angle, repeat

steps 3 to 6

7. Retighten the lock nut on the threaded rod – tightening torque 5 Nm.
8. Check the mode of operation of the quarter turn actuator (

section 8.4)

End position for left turning – opening process valve

1

2

3

4

5

1 Lock nut with sealing ring

2 Threaded rod

3 Spring disc

4 Piston

5 Adjustment range of the outer end

position (see technical data)

Fig. 13

1. Supply compressed air and open the process valve. The pistons move to the

outer end position. This fixes the threaded rod – dependent on the current set-
ting. Loosening of the lock nut will then not accidentally change the current
setting.

2. Screw down the lock nut with sealing ring. If the threaded rod has loosened,

retighten it by hand until a light resistance is felt.

3. Vent the DAPS and close the process valve. The pistons move to the inner end

position.

4. Adjust the end position:

Observe that a complete turn of the threaded rod can change the swivel angle
approx. 1.5° to 3.5° – dependent on the product design.
– Turning the threaded rod clockwise reduces the swivel angle.
– Turning the threaded rod anti-clockwise increases the swivel angle.

5. Supply compressed air and open the process valve. The pistons run against the

threaded rods into the outer end position.

6. Check the position of the process valve. To change the swivel angle, repeat

steps 3 to 6.

7. Retighten the lock nut on the threaded rod – tightening torque 5 Nm.
8. Check the mode of operation of the quarter turn actuator (

section 8.4)

8.4 Check the mode of operation of the quarter turn actuator
• Check in cyclical tests, through alternating pressurisation and, if necessary,

venting, whether the quarter turn actuator takes the required positions.

• If necessary, adjust the end positions to the extent the quarter turn actuator

offers this possibility (

section 8.1).

8.5 Emergency handwheel operation
Before operating the handwheel:
1. Make sure the actuator is free of pressure.
2. Unhook the locking spring.
3. For the DAPS..R..-F..-MW-T6 “low temperature” version: Remove the protective

cover from the display.

Opening the process valve with the handwheel

DAPS..R-… (double-acting)

DAPS..RS-… (single-acting)

• Turn the handwheel

anti-clockwise

until the indicator moves

inwards

(

Fig. 6).

• Turn the handwheel

anti-clockwise

until the indicator moves

outwards

(

Fig. 7).

Fig. 14

Closing the process valve with the handwheel

DAPS..R-… (double-acting)

DAPS..RS-… (single-acting)

• Turn the handwheel

clockwise until

the indicator moves

outwards

(

Fig. 6).

• Turn the handwheel

clockwise until

the indicator moves

inwards

(

Fig. 6).

Fig. 15

Before pneumatically actuating the actuator again:
4. Turn back the handwheel until the indicator is located centrally once again

(neutral position,

Fig. 5).

5. Hook in the locking spring again.
6. For the DAPS..R..-F..-MW-T6 “low temperature” version: Replace the protective

cover on the display.

9

Maintenance and care

If used as intended in the operating instructions, the device will be maintenance-
free.

10

Disassembly

Warning

Danger of injury due to uncontrolled movements.
• Switch the tubing system pressureless before dismantling.

1. If necessary, remove any existing limit switches.
2. Remove the pneumatic switching valve.
3. Loosen the screws on the flange of the process valve.
4. Remove the quarter turn actuator (if necessary including mounting adapter and

coupling extension) from the process valve.

11

Troubleshooting

• Please contact Festo.

Advertising
This manual is related to the following products: