Product-specific terms and abbreviations – Festo Контроллер крайних положений SPC11 User Manual

Page 11

Advertising
background image

Contents and general safety instructions

IX

Festo P.BE-SPC11-DGCI-EN en 1406d

Product-specific terms and abbreviations

The following product-specific abbreviations are used in this
manual:

Term/abbrevi-
ation

Meaning

0-signal

Input or output supplies 0 V

1-signal

Input or output supplies 24 V

Drive

The term drive is used in this manual for the linear unit (DDLI, DGCI-... or
DGP(I)(L)-...), cylinder (DDPC, DNC...) or rotary drive (DSMI-...).

O

Digital output

Cushioning stage

The positioning behaviour is determined by the amplification and cushioning
stages. The cushioning stage serves to optimize the approach behaviour when
moving to the end positions.

I

Digital input

PLC/IPC

Programmable logic controller/industrial PC

System parameters

Characteristic value which describes the system structure, the features and
components of the drive used.

Parameters

Parameters which must be set in order that the system can be operated.
The amplification stage, the cushioning stage and the system parameter
belong here.

Teach procedure

During the teach procedure the SPC11 checks the set parameters, learns the
position of the mechanical fixed stops as well as various characteristic system
values and saves them in the integrated EEPROM.

Amplification stage

The amplification stage influences the acceleration behaviour of the drive,
for example. The amplification stage should usually be set as specified in the
“Drive-Specific Supplement” manual. If the positioning behaviour is optim-
ized later, only the cushioning stage should be modified.

Advertising