Festo Контроллер крайних положений SPC11 User Manual

Page 23

Advertising
background image

1. Installation instructions for the DGCI or DDLI

1-11

Festo P.BE-SPC11-DGCI-EN en 1406d

If the DGCI or DDLI is ordered with screw connectors – Stand-
ard (no modular system feature) or modular system feature
“QD” or “QR”:

Work port 2 of the proportional directional control valve
must be connected to the drive connection of the screw
connector with blue releasing ring.

Work port 4 of the proportional directional control valve
must be connected to the drive connection of the screw
connector with black releasing ring.

Linear drive type DGCI/DDLI (

6 )

With the DGCI or DDLI, use only:

drives of type DGCI or DDLI.

Permitted combinations of drives and valves, drive diam-
eter, drive lengths and mass loads, see “Parameters for
the DGCI or DDLI” in chapter 2.

Drives with air supply on both sides (for good positioning
behaviour).

Fit the drive horizontally or vertically.

Connect the drive, the guide, the potentiometer and the
load free of play in the direction of movement and flush
with each other.

If necessary, provide a sufficiently large supply of energy
in order to minimize the effects of transverse forces on
the positioning behaviour.

Lubricate the guide of the drive at maintenance intervals
as specified in the operating instructions for the drive
(see operating instructions for the drive or the guide).

Advertising