Festo Кабели и принадлежности User Manual

Page 30

Advertising
background image

2. Fitting

2−4

Festo P.BE−SPC200−SMX−1−EN en 0503b

2.1

Fitting and removing the stepping motor indexer module

Caution
Modules may be damaged if they are not handled corĆ
rectly.

S Do not therefore touch the contacts of the components.

S Observe the regulations for handling electrostatically

sensitive components.

Discharge yourself electrostatically before fitting or removing
components in order to protect the components against disĆ
charges of static electricity.

Note the following when fitting the module:

ć

The stepping motor indexer module can be fitted as deĆ
sired into any of the slots 2 to 6. Individual identification
of all fitted modules takes place automatically.

ć

The axis identifiers are assigned to the modules or the
connected axes in ascending order from left to right withĆ
out gaps.

ć

Maximum 3 stepping motor indexer modules can be
fitted.

ć

If a stepping motor indexer module is fitted next to the
diagnostic module, a control panel cannot be connected
because of the plug for the cable to the stepping motor
controller.

The modules are fastened on the rack with the aid of a lockĆ
ing lever. A tool is not therefore required for fitting or removĆ
ing a module.

Advertising