3. Installation

3−3

Festo P.BE−SPC200−SMX−1−EN en 0503b

3.1

General instructions

Warning
Before carrying out installation and/or maintenance work,
switch off the following in the sequence specified:

1. the compressed air supply

2. all load and operating voltage supplies on the SPC200

and the connected components of the positioning
system.

Load and operating voltage supplies:

ć

The load voltage supply for field devices and proportional
directional control valves (plug X2, pin 1)

ć

The load voltage supply for the outputs (plug X6/X8,
pinĂ8)

ć

If applicable, the load voltage supply on the axis interface
string

ć

The operating voltage supply for the internal electronics
of the SPC200 and field devices (plug X2, pin 2)

ć

The sensor supply on the stepping motor indexer module
(connection SIGNALS, pin 4)

ć

The operating voltage supply on the stepping motor conĆ
troller

You can thereby avoid:

ć

undesired movements of the connected actuators

ć

uncontrolled movements of loose tubing

ć

undefined switching states

ć

damage to the electronic components.

Advertising