Troubleshooting guide – Graymills Liftkleen L-Series OMI User Manual

Page 10

Advertising
background image

9

TROUBLESHOOTING GUIDE

ELECTRICAL

CONDITION

POSSIBLE CAUSE

CORRECTION

Pump does not run.

Electrical service to motor is not

Check electrical supply and

correct.

correct.

Motor is burned out.

Replace motor or return pump to
factory for repair.

Pump runs but does not agitate.

Pump rotation is incorrect

Reverse any two electrical supply

(3 Phase Power).

lines to motor. (Correct rotation is
CCW - see label.)

Pump runs but is noisy. (Minor

Cavitation due to low liquid level.

Raise liquid to correct level.

sound created by liquid flow
through pump is normal.)

Tank does not reach operating

Electrical supply is not on.

Check and correct electric

temperature.

service.

Thermostat is set too low.

Raise thermostat temperature.

Faulty heater.

Check and replace if necessary.

Heating contactor is faulty.

Check and replace if necessary.

Tank takes too long to heat up.

Electrical supply voltage is

Check and correct if necessary.

(See Figure 12 for heat-up times).

incorrect.

One element of the tri-element

Check heater elements and

heater is burned out.

replace heater if necessary.

Excessive heat loss due to

Lower rack and lid when unit is

open lid.

not in use.

Heater Timer

Tank does not reach operating

115V, Single phase power

Turn on.

temperature.

supply off.

Timer actuating tripper not

Attach tripper.

attached.

Timer actuating tripper incorrectly

Position correctly.

positioned.

Faulty timer.

Replace.

Faulty transformer.

Replace.

Faulty contactor.

Replace.