TABLE 2

LIFTKLEEN PLATFORM LOAD CAPACITY

LIFTKLEEN

CYL.

WORKING LOAD AT VARIOUS AIR PRESSURES

BASIC MODEL

DIA.

70 PSI

80 PSI

90 PSI

100 PSI

110 PSI

LKR 36

330

400

480

550

630

LKR 36 IL

425

740

860

980

*___

LKR 48

230

300

380

450

530

LKR 48 IL

525

640

760

880

990

LKR 60

325

440

560

680

790

LKR 60 IL

5˝ (2)

1150

1385

1620

1850

*2090

LKD 60

325

440

560

680

790

LKD 60 IL

5˝ (2)

1150

1385

1620

1850

*2090

LKD 72 IL

5˝ (2)

1050

1285

1520

1750

1990

IL = Increased Lift Capacity because of larger cylinder.
*___ Exceeds rated capacity.

NOTE: The above working loads are calculated at 60% of gross cylinder capacity less rack weight. This is required

for good agitation.

Average agitation cycle (up and down) will be approximately 30 per minute. This will vary with the load, air
pressure and volume.

Pump agitation is continuous regardless of load.

TABLE 3

LIFTKLEEN AIR CONSUMPTION

(5 IN. STROKE)

STROKES

“UP” ONLY

“UP” AND “DOWN”

CYLINDER

PER

(SCFM)

(SCFM)

SIZE (IN.)

MODELS

MINUTE

60 PSI

80 PSI

100 PSI

60 PSI

80 PSI

100 PSI

4

LKR-36, -48

20

5.4

6.9

8.4

8.7

10.8

13.0

5

LKR-36, -48(Heavy)

20

8.5

10.8

13.2

13.6

17.1

20.5

LKR-60
LKD-60, -72

5 (2)

LKR-60

20

17.2

21.9

26.5

27.5

34.5

41.3

LKD-60, -72
(Heavy Lift)

4

LKR-36, -48

40

7.2

9.2

11.2

11.6

14.4

17.4

5

LKR-36, -48(Heavy)

40

11.4

14.4

17.6

18.2

22.8

27.4

LKR-60
LKD-60, -72

5 (2)

LKR-60

40

23.8

29.2

35.4

36.8

46.0

55.2

LKD-60, -72
(Heavy Lift)

Advertising