FIGURE 4b

PNEUMATIC SYSTEMS

APPLICATION: Hot units with pneumatic lid

DESCRIPTION: Pneumatic system consisting of:

1. Control box with a 2 position (ON-OFF)

Oscillate Selector Switch, Start, Reset, and
Emergency Stop Buttons.

2. Mechanical type valves
3. Lid Lockout.

SEQUENCE OF OPERATIONS:

START: Lid Closed, Rack Down

LOADING:
1. Depress Reset button, lid will close

automatically

AGITATION:
1. Turn Oscillate Selector switch to ON position
2. Depress Start Button, lid will close

automatically

SOAK:
1. Turn Oscillate Selector to OFF position
2. Depress Start button, lid will close

automatically

LID LOCKOUT: Lid activated switch overrides all
other selector switches and prevents rack from
going to the UP position before the lid is fully
opened.

See Drawing #796PD37641