Figure 4d – Graymills Liftkleen L-Series OMI User Manual

Page 23

Advertising
background image

22

FIGURE 4d

ANTI-TIE DOWN SYSTEMS

APPLICATION: All units with Anti-Tie Down

devices

DESCRIPTION: Pneumatic system consisting of:

1. Control box with a 2 position (ON-OFF)

Oscillate Selector Switch, Start, Reset, and
Emergency Stop Buttons.

2. Anti-Tie Down Device
3. Mechanical type valves
4. Lid Lockout

SEQUENCE OF OPERATIONS:

START: Lid Closed, Rack Down

LOADING:
1. Depress both buttons on the Anti-Tie Down

device simultaneously and hold until the lid
opens completely and the rack is in the fully
upright position, then release the Anti-Tie
Down buttons

AGITATION:
1. Turn Oscillate Selector switch to ON position
2. Depress both buttons on the Anti-Tie Down

device simultaneously and hold until the rack
is in the down position and the lid closes
completely, then release the Anti-Tie Down
buttons

SOAK:
1. Turn Oscillate Selector to OFF position
2. Depress both buttons on the Anti-Tie Down

device simultaneously and hold until the rack
is in the down position and the lid closes
completely, then release the Anti-Tie Down
buttons

LID LOCKOUT: Lid activated switch overrides all
other selector switches and prevents rack from
going to the UP position before the lid is fully
opened.

See Drawing #796PD37642-1

Advertising