TABLE 4

LIFTKLEEN ELECTRICAL CURRENT REQUIREMENTS

HEATER AMPERAGE

VOLTAGE/PHASE

1 Heater (4500 W)

2 Heaters (9000 W)

3 Heaters (13,500 W)

240 V/1-Ph

18.8

37.5

56.3

240 V/3-Ph

10.8

21.7

32.5

480 V/3-Ph

5.4

10.8

16.2

575 V/3-Ph

4.5

9.0

13.5

Note: Add the corresponding motor amps below to the above heater amps to find the full load amperage.

VOLTAGE/PHASE

MOTOR AMPERAGE (1-1/2 H.P., 1725 RPM)

230 V/1-Ph

10.5

230 V/3-Ph

4.6

460 V/3-Ph

2.3

575 V/3-Ph

2.0

TABLE 5

LIFTKLEEN FILTERS

Filter Housing #742-06154 is used with the following cartridge assemblies.

Cartridge

Particle Retention

Element

Cartridge #

Type

Size

Number

742-06317

Stacked Disc

3-5 Micron

742-06318

742-06319

Disposable Bag

50 Micron

742-06320

742-06332

Strainer

590 Micron (30 Mesh)

742-06331

742-06243

Strainer

150 Micron (100 Mesh)

742-06244

_

Strainer*

100 Micron (150 Mesh)

742-06379

_

Strainer*

74 Micron (200 Mesh)

742-06380

_

Strainer *

30 Micron (2140 Mesh)

742-06381

*These are optional elements (not cartridge assemblies). They can be used in place of the standard

elements (30 Mesh and 100 Mesh) in cartridge assemblies #742-06332 and 742-06243.