HEATED AND UNHEATED
MACHINES –
AQUEOUS/SOLVENT

WARNING

These units have moving parts, pinch-points
and close tolerances. Always stand clear of lift
platform and lid when operating as the lid
could unexpectedly open or the platform
operate. Never raise lift platform with lid
closed. Keep hands and fingers away from
tank when operating platform. (See the
OPERATION section.)

Unit must be properly grounded to prevent
electric shock hazard. Connect only to three
prong outlet. Should cord become cracked,
frayed or damaged in any way, it should be
repaired immediately by a qualified electrician.
Never use an extension cord.

Since operator safety at all times is a priority,
we strongly recommend that, whether or not
required by local code, this equipment be
connected only into a power supply equipped
with a “Ground Fault Interrupter” (GFI). All
electrical connections should conform to
national/local codes and be made by qualified
personnel.

CAUTION

Inspect optional pump, optional heater and all
electrical cords, plugs, and fusible link each
time unit is cleaned. Do NOT use if any wear or
damage is noticed until impaired components
are repaired or replaced. Never operate if
fusible fire link is not in place and functional.

Fill tank to recommended operating capacity
range before plugging in power cord. (See
Table 1, p. 12.)

WARNING

DO NOT perform any maintenance work on
Liftkleen without having the air shut-off valve
in the “Off” position and main air lines to
cylinders disconnected. Disconnect electrical
power. Follow lock out procedures.

CAUTION

If any cleaning solutions are splashed on
clothing, remove wet clothing promptly and
thoroughly wash body areas that have been in
contact with the solution. Do NOT permit
saturated clothing to remain in contact with
skin. Consult manufacturer’s Material Safety
Data Sheet (MSDS).

!

!

!

!

NOTE

If you have purchased a heated unit with a carbon
steel tank, observe the following before using:
Water-based cleaning materials will generate
steam and water vapors. Surfaces above the liquid
level will be subject to rusting (this condition exists
with any manufacturer’s unit). This is primarily sur-
face rust and does not appreciably affect the
serviceability of the unit. However, if your cleaning
requirements cannot tolerate any rust or
contamination, please contact the factory for
information on stainless steel models before
putting the unit into service. Also, be sure your
cleaning material contains a rust inhibitor. (Check
with your cleaning fluid supplier.) The Graymills
Warranty does not cover rusting of carbon steel
units used with water-based material.

UNHEATED MACHINES –
SOLVENT

WARNING

Do NOT install near open flames or heat. Do
NOT smoke near parts cleaner.

Be sure to follow label instructions provided
with any fluid used in this unit. Use only
combustible fluids with a flash point of 104°F
or higher. Graymills recommends Super or
Regular Agitene

®

(flashpoint approx. 105°F). Do

NOT use flammable materials such as gasoline
or alcohol(under 100°F flashpoint). Use of such
unauthorized materials can cause a health and
safety hazard which might result in serious per-
sonal injury or death. If you have any questions
regarding the correct fluids to use in this unit,
call Graymills at (773) 248-6825 and ask for
Customer Service.

Do NOT contaminate cleaning compounds
with any flammable materials (less than 100°F
flashpoint), such as gasoline, alcohol, etc.
Drain parts to be cleaned of any flammable
material before placing inside cleaning tank.
Even small quantities can create a dangerous
safety hazard.

CAUTION

Unit is equipped with a fusible safety link
cover mechanism designed to support the
open lid at a slightly forward angle. In the
event of a fire, the fusible link will melt at 165°F
permitting the lid to slam shut, reducing
oxygen supply to the fire.

!

!