VP-4x4K - Connecting the VP-4x4K

11

5.4

Cascading Machines

You can cascade up to 16

VP-4x4K units with control from a PC or serial

controller.

To cascade 16 individual

VP-4x4K units via RS-485, as illustrated in the example

in

Figure 5

, do the following:

1. Connect the sources and acceptors (see

Section 5.1

).

2. Connect the RS-232 port of the first

VP-4x4K unit to a PC.

3. Connect the RS-485 terminal block port on the first

VP-4x4K unit to the

RS-485 port on the second

VP-4x4K unit and so on, connecting all the

RS-485 ports.

4. Set the first

VP-4x4K unit as Machine # 1 and the following VP-4x4K units

as Machine # 2 to Machine # 16 (see

Section 6.4

).

5. On the first and last

VP-4x4K units, set the RS-485 TERM DIP-switch to ON,

terminating the RS-485 line at 120Ω (see

Section 5.6

), and set this DIP-

switch to OFF on the other

VP-4x4K units.