9 communication parameters, Communication parameters, 9communication parameters – Kramer Electronics VP-4x4K User Manual

Page 40

Advertising
background image

36

VP-4x4K - Communication Parameters

9

Communication Parameters

VP-4x4K communication parameters are listed here.

EDID

EDID data is passed between Input 1 and Output 1

RS-232

Protocol 2000

Protocol 3000 (Default)

Baud Rate:

9600

Baud Rate:

115,200

Data Bits:

8

Data Bits:

8

Stop Bits:

1

Stop Bits:

1

Parity:

None

Parity:

None

Command Format:

HEX

Command

Format:

ASCII

Example (Output 1 to

Input 1):

0x01, 0x81, 0x81,

0x81

Example (Output

1 to Input 1):

#AV 1>1<CR>

Switching Protocol

P2000 -> P3000

P3000 -> P2000

Command:

0x38, 0x80, 0x83,

0x81

Command:

#P2000<CR>

Front Panel:

Press and hold

Output 1 and

Output 3

simultaneously

Front Panel:

Press and hold

Output 1 and

Output 2

simultaneously

Ethernet

Default Settings

Reset Settings

IP Address: 192.168.1.39 Power cycle the unit while holding in the Factory Reset button,

located on the rear panel of the unit.

TCP Port #: 5000
UDP Port #: 50000