VP-773 - The OSD Menu

To setup and activate the alert system on the VP-773:

1. Set the dedicated EAS Ethernet connection port type and port number

through which the VP-773 will be listening, as a client, to intercept alerts.

By default, the dedicated EAS port settings are TCP, 5005. To change these

setting see the

“Emergency Alert Configuration” in the table in

Section

12.4

.

2. Make sure that the VP-773 is connected to Ethernet.

3. Make sure that Alert System in the Miscellaneous menu is set to On (see

Section

6.8

).

The VP-773 is now ready to receive any alert and display it.

6.8.2.1 EAS Requirements

The following table specifies the EAS requirements:

Text Length Definitions

Attribute Name

Max Size

Status

02

Certainty

02

Urgency

02

Severity

02

Event

54

Headline

54

Description

052

Instruction

052

Sender

02

Sent

02

Max 30 contiguous chars per word

Output Resolution

The output resolution needs to be at least 1280x768