Sunlight Supply Grozone Control SCC1 Temperature, Humidity and CO2 Controller Simple One Series User Manual

Page 3

Advertising
background image

3 of 12

Grozone SCC1 Advanced User Guide – March 2012

www.grozonecontrol.com

2- TEMPERATURE AND HUMIDITY CONTROL WITH FAN

(AND OPTIONAL HEATER)


To use this mode, you connect your cooling Fan into the FAN 120V Output, set the Slide Switch to
“Cooling & Dehumidifying”
position.

















COOLING

DEHUMIDIFYING


CONTROL ACTION

DAY OPERATION

NIGHT OPERATION

BASIC
OPERATION
(lowest priority)

START / STOP THE FAN
To maintain the temperature and humidity around the DAY SETPOINTS
(+/- 2°F or +/- 1°C for temperature, and +/-2% for humidity)

Same as Day

ACTION OF
HIGHER
PRIORITY

STOP THE FAN TEMPORARILY
When CO2 output is activated

None, CO2 is enabled during
the Day only

RESUME FAN OPERATION AFTER A 10-MINUTE ON-DELAY
When CO2 output is deactivated when CO2 level is reached

ACTION OF
HIGHER
PRIORITY

STOP THE FAN
When Low Temperature Limit is reached in the event of excessive
cooling caused by cold and humid air intake not allowing to reach the
dehumidifying setpoint, even though cooling setpoint has been reached
already.

Same as Day

ACTION OF TOP
PRIORITY

USE THE FAN FOR COOLING ONLY
in the unlikely event of a humidity sensor failure

Same as Day

ACTION OF TOP
PRIORITY

MAINTAIN THE FAN ON
in the unlikely event of a temperature sensor failure

Same as Day

OPTIONAL SAFETY HEATING

CONTROL ACTION

DAY OPERATION

NIGHT OPERATION

BASIC
OPERATION
(lowest priority)

TURN ON / TURN OFF THE HEATER
To save your plants if the lamps alone are not able to ensure a minimum
temperature in your room in a cold weather.

Same as Day

ACTION OF
HIGHER
PRIORITY

NONE

Same as Day

ACTION OF TOP
PRIORITY

MAINTAIN THE HEATER OFF
in the unlikely event of a temperature sensor failure

Same as Day


Advertising