11 dac control 3 (address 14h), 1 dac1-4 attenuation, 2 mute dacx – Cirrus Logic CS4244 User Manual

Page 53: 12 dac control 4 (address 15h), 1 vq ramp, 2 power down dacx, Power, Down dacx, Bits, Power down dacx

Advertising
background image

DS900F1

53

CS4244

6.11 DAC Control 3 (Address 14h)

6.11.1

DAC1-4 Attenuation

Sets the mode of attenuation used for the DAC1-4 path.

Note:

Please see

Section 4.6.5 Volume Control

for more details regarding the attenuation modes.

6.11.2

Mute DACx

Mutes the DACx signal.

6.12 DAC Control 4 (Address 15h)

6.12.1

VQ Ramp

Ramps common mode voltage “VQ” down to ground. This bit needs to be set before asserting reset pin.

6.12.2

Power Down DACx

Powers down the DACx path.

7

6

5

4

3

2

1

0

Reserved

DAC1-4 ATT

Reserved

Reserved

MUTE DAC4

MUTE DAC3

MUTE DAC2

MUTE DAC1

DAC1-4 ATT

Attenuation events happen:

0

On a soft ramp

1

Immediately

MUTE DACx

DACx is:

0

Not Muted

1

Muted

7

6

5

4

3

2

1

0

VQ RAMP

Reserved[1:0]

Reserved

PDN DAC4

PDN DAC3

PDN DAC2

PDN DAC1

VQ RAMP

Effect:

0

VQ is set at nominal level (VA/2)

1

VQ is ramped from nominal level to ground.

PDN DACx

DACx is:

0

Powered Up

1

Powered Down

Advertising