2 analog audio input, 2 analog audio input -4, Figure 4-6. ck49x analog properties -4 – Cirrus Logic CK4970x4 User Manual

Page 38

Advertising
background image

Programming the DSP on the CK49x Evaluation Board

CK49x User’s Manual

DS898CK7

Copyright 2012 Cirrus Logic, Inc

4-4

4.3.2 Analog Audio Input

To deliver data to the DSP via 6ch ADC, select “Analog” as the Input Source following the same steps

used in selecting SPDIF as described in the previous section. Double click the “Audio In” block to see the

signal flow. Right-clicking the “ADC” block and selecting Device Properties will display the CODEC
Properties

dialog as illustrated in

Figure 4-6

. The Master/Slave property must always be set to Master to

indicate that the ADC will master SCLK and LRCLK as described in

Section 1.3.20 “Audio Clocking” on

page 1-10.

Figure 4-6. CK49x Analog Properties

The dialog windows of both SPDIF RX Properties and CODEC Properties allow the user to set the

following parameters:

• Input Sampling Frequency Range - Select the Fs range of the ADC on the CS42448 CODEC in

accordance to the input stream where

- 1FS = 32 kHz, 44.1 kHz, or 48 kHz
- 2Fs = 64 kHz, 88.2 kHz, or 96 kHz
- 4FS= 128 kHz, 176.4 kHz, or 192 kHz

• Master/Slave settings for the SCLK & LRCLK pins on the CS8416.
SPDIF input only Mux: RX0 - RX3, and ‘NONE’. Choosing ‘NONE’ forces the CS8416 to pass the

DSP clock that comes in on the OMCK pin to MUXED_MCLK (RMCK). Use this setting when using

the ADC.

Analog input only - Enable microphone input.