Prospector series poppet valves – Norgren Prospector Series Datasheets User Manual

Page 13

Advertising
background image

Littleton, CO USA

Phone: 303-794-2611

www.norgren.com

VAL-12-13

Prospector Series Poppet Valves

Solenoid Pilot Operated Inline & Subbase Valves

Options Information

For optional features, note the valve model number that comes closest to the desired valve from the preceding order table. Change the model
number as shown in the following diagram to obtain the desired option. For example: the ordering table on VAL-12-9 shows D1022C-00-CY, a 3-
port/2-position valve with a solenoid operator, spring return and non-locking override. To use this valve with a locking override change the last two
digits to CE, as shown below. To order operators with fluorocarbon elastomers, please contact Technical Services. See following page for optional
operator voltages and connectors.

D

1

0

2

2

C

0

0

C

E

Position in Model Number

1

2

3

4

5

6

7

8

9

10

Vacuum Service

For on-off application of vacuum, use a

normally closed 2-port/2-position (2-way) valve.
When the valve is actuated, vacuum will be
applied to the outlet port.

For selecting alternately between vacuum and

pressure, use a normally open 3-port/2-position
(3-way) valve. Connect the vacuum to the exhaust
port and pressure to the inlet port. When the
valve is actuated, vacuum will be applied to the
outlet port.

For selecting alternately between vacuum and

vent, use a normally open 3-port/2-position (3-
way) valve. Connect the vacuum to the exhaust
port and vent the inlet port. When the valve is
actuated, vacuum will be applied to the outlet
port.

In addition, a 4-port/2-position (4-way) valve

can be connected the same way as 3-port/2-
position (3-way) valves for selecting alternately
between vacuum and pressure or vacuum and
vent. That is, connect the vacuum to the exhaust
port and pressure or vent to the inlet port. When
the valve is actuated, the cylinder ports (outlets)
will be alternately switched between vacuum and
pressure or vacuum and vent.

Optional Operator for

Weight

Basic 1/4" & 1/2" Valves

lbs. (kg)

C F

Locking override,

1.00 (0.45)

low wattage

7

Indicator Pin (Basic 1/2" valve)

8

Indicator Pin (Basic 1" valve)

J

Vacuum Service†

Optional Operator Classification: CY, CC, CE, CF, P1: IP65
(NEMA 4); C0, C1: IP30 (NEMA 1); X1: EEx d 11B T4
(NEMA 7C, 7D, 8C, 8D, 9E and 9G. Solenoids using
specified optional coils, meet the requirements of
Underwriters Laboratories and Canadian Standards
Association for use in hazardous locations as defined in the
National Electric Code (ANSI CI): Class I, Groups C & D;
Class II, Groups E, F & G.
Power Requirements: CC: 8 WDC; 8 WAC; CE, CY: 6 WDC, 7
WAC; CF: 2 WDC, 3.5 WAC; C0, C1, P1, X1: 12 W
** Orifice Diameter: C0, C1, X1: 1.2mm (3/64")

Pilot Supply: Internal (Convertible to External)
Solenoid Exhaust Port: P1: 1/8" PTF; X1: 10-32 UNF;
C0, C1: Not Threaded.

To calculate the weight of a valve and optional operator take the weight given for the relevant valve from the ordering tables, subtract either 1.65 lbs (0.75 kg) for a
CC operator, or 1.00 lbs. (0.45 kg) for a CE or CY operator, and add the weight given above for the appropriate optional operator.

For example: For D1022C-00-CY has a listed weight of 2.50 lbs (1.13 kg). To convert this from a non-locking override to a hazardous location, locking override, i.e.
D1022C-00-X1

1.13 - 1.00 + 1.57 = 1.70 kg (3.74 lbs).

Optional Solenoid Operators**

Weight

lbs. (kg)

C 0

1/2" NPT conduit

without override

1.11 (0.50)

C 1

1/2" NPT conduit,

locking override

P 1

1/2" NPT conduit,

2.05 (0.93)

non-locking override

1/2" NPT conduit,

X 1

hazardous location,

1.57 (0.71)

locking override

Example model number is a 3-port/2-position (3-way) valve
with a solenoid operator, spring return, and locking override.

Advertising