Prospector series poppet valves – Norgren Prospector Series Datasheets User Manual

Page 61

Advertising
background image

Prospector Series Poppet Valves

Littleton, CO USA

Phone: 303-794-2611

www.norgren.com

VAL-12-61

9 & 10 Solenoid Operators

Standard Solenoid Operators with Cable Grip Connector

for use with Basic 1" & 2" Valves

(Optional for use with Basic 1/4" & 1/2" Valves)

CC = Single solenoid, nonlocking override, 8 WAC & DC.
CR = Twin solenoid, nonlocking override, 8 WAC & DC.
CU = Momentary signal solenoid, nonlocking override, 8 WAC & DC
CK = CCW/24VDC & surge protector cable grip connector.*

Standard Solenoid Operators with Cable Grip Connector

for use with Basic 1/2" & 1/4" Valves

CY = Single solenoid, nonlocking override, 7WAC, 6WDC
CE = Single solenoid, locking override, 7WAC, 6WDC
CS = Single solenoid, no override, 7WAC, 6WDC

CZ = Single solenoid, nonlocking override, 3.5WAC, 2WDC
CF = Single solenoid, locking override, 3.5WAC, 2WDC
DA = Single solenoid, no override, 3.5WAC, 2WDC

CW = Twin solenoid, nonlocking override, 7WAC, 6WDC
CN = Twin solenoid, locking override, 7WAC, 6WDC
CP = Twin solenoid, no override, 7WAC, 6WDC

CV = Momentary signal solenoid, nonlocking override, 7WAC, 6WDC.

Optional Solenoid Operators

C0 = Single, no override, 1/2" conduit.
C1 = Single, locking override, 1/2" conduit.
C2 = Single, no override, junction box.
C3 = Single, locking override, junction box.
C4 = Single, no override, low pressure, 1/2" conduit.
C8 = Single, locking override, high pressure, 1/2" conduit.
CT = Single, no override, high temperature, 1/2" conduit.

D0 = Momentary Signal, no override, 1/2" conduit.
D1 = Momentary Signal, locking override, 1/2" conduit.
D2 = Momentary Signal, no override, junction box.
D3 = Momentary Signal, locking override, junction box.
D4 = Twin, no override, 1/2" conduit.
D5 = Twin, locking override, 1/2" conduit.
D6 = Twin, no override, junction box.
D7 = Twin, locking override, junction box.
D8 = Twin, locking override, high pressure, junction box.

E1 = Single, nonlocking override, 1/2" conduit.
E3 = Single, nonlocking override, junction box.
E8 = Single, nonlocking override, high pressure, 1/2" conduit.

F4 = Momentary Signal, nonlocking override, 1/2" conduit.
F5 = Momentary Signal, nonlocking override, junction box.
F6 = Twin, nonlocking override, 1/2" conduit.
F7 = Twin, nonlocking override, junction box.

X0 = Single, no override, hazardous location.
X1 = Single, locking override, hazardous location.
X2 = Momentary Signal, no override, hazardous location.
X3 = Momentary Signal, locking override, hazardous location.
X4 = Twin, no override, hazardous location.
X5 = Twin, locking override, hazardous location.

9 & 10 Air Operators
A1 = Single, PTF Threads

AA = Single, BSPP Threads

A4 = Twin, PTF Threads

A6 = Momentary signal, PTF Threads
Af = Momentary Signal, BSPP Threads

9 & 10 Manual & Mechanical Operators
MA = Plunger, spring return.

MB = Palm button, spring return.

MC = Hand Lever, horizontal, spring return.
MD = Hand Lever, horizontal, detented.
ME = Hand Lever, vertical, spring return.
MF = Hand Lever, vertical, detented

MG = Clevis Lever, horizontal, spring return.
MH = Clevis Lever, vertical, spring return.

MJ = Roller Lever, horizontal, spring return.
MK = Roller Lever, vertical, spring return.

ML = Foot Pedal, horizontal, spring return.
MM= Foot Pedal, vertical, spring return.

Voltage & Connector Options for Standard Solenoid Operators
Specify the desired valve model number (from pages 8, 10, or 12)
plus the desired option part number from the following tables. When
ordering options for the CN, CP, CR, CU, CV, and CW operators,
specify (Qty 2) after the option part number.

Operator

CD, CE, CN, CP,

DA,

CC,

Optional Voltages

CS, CV, CW, CY

CF, CZ

CR, CU

12V/60Hz/50Hz

54452-34

24V/60Hz/50Hz

54452-35

54469-24

54458-63

48V/60Hz/50Hz

54452-36

120V/60Hz, 110V/50Hz

Standard

54469-23

Standard

240V/60Hz, 220V/50Hz

54452-37

54458-62

6VDC

54469-25

12VDC

54452-32

54469-21

54458-64

24VDC

54452-33

Standard

54458-60

110VDC

54469-26

DA, CE, CF,

CN, CP, CS,

CC,

Optional Connectors

CV, CW, CY, CZ

CR, CU

Cable Grip with Indicator Light

12VDC or AC

54257-54

24VDC or AC

54934-09

54257-55

120VDC or AC

54934-03

54257-56

220VDC or AC

54257-57

1/2" NPT Conduit

54934-04

54933-18

5-ft. Molded Cord

54934-06

54933-17

5-ft. Molded Cord, Indicator Light,
Surge Protection, Polarity Independent

24VAC or DC

54934-11

54933-08

48VAC or DC

54934-12

54933-10

120VAC or DC

54934-14

54933-12

240VAC or DC

54934-16

54933-14

Advertising