Prospector series poppet valves – Norgren Prospector Series Datasheets User Manual

Page 60

Advertising
background image

Prospector Series Poppet Valves

VAL-12-60

Littleton, CO USA

Phone: 303-794-2611

www.norgren.com

Prospector Popped Valve Product Number System

The following chart is intended to be used only as a general guide to the model number system. It is not designed to
"build" model numbers.

POSITION IN MODEL NUMBER

1 Valve Type
A = 2-Port/2-Position, Normally Closed.
B = 2-Port/2-Position, Normally Open.
C = 3-Port/2-Position, Multi-Directional.
D = 3-Port/2-Position, Normally Closed.
E = 3-Port/2-Position, Normally Open.
F = 4-Port/2-Position (4-way).
G = 4-Port/2-Position, (3-way twin, Normally Closed).

7 & 8 Time Delay
00 = None
01 = 0 to 5 seconds.

TDO

Normally closed.

02 = 0 to 5 seconds.

TDR

Normally closed.

03 = 0 to 60 seconds.

TDO

Normally closed.

04 = 0 to 60 seconds.

TDR

Normally closed.

05 = 0 to 60 seconds.

TDOR

Normally closed.

09 = 0 to 60 seconds.

TDO

Normally open.

10 = 0 to 60 seconds.

TDR

Normally open.

22 = 0 to 60 seconds.

Delayed One Shot.

23 = 0 to 60 seconds.

One Shot

Normally closed.

24 = 0 to 60 seconds.

TDO

Normally closed.

2 Mounting Style
1 = Inline, PTF Threads
A = Inline, BSPP Threads
2 = Subbase valve with subbase, PTF Threads
3 = Subbase valve without subbase, PTF Threads

5 Port Size PTF
2 = 1/4"

Ports

3 = 3/8"

Ports

4 = 1/2"

Ports

5 = 3/4"

Ports

6 = 1"

Ports

7 = 1-1/4" Ports
8 = 1-1/2" Ports
9 = 2"

Ports

0 = Subbase valve without subbase.

6 Internal Variation
B = Internal Pilot Supply with unrestricted passage.
C = Internal Pilot Supply with check valve.
E = Sustaining Bleed Operation. Use only with momentary

signal solenoid operator. Has an internal pilot supply.

F = Bleed Operation. Has an internal pilot supply with flow

restrictor. Use only with A1 and A4 air operators.

H = External Pilot Supply.
J = Vacuum Service. Has an external pilot supply

with heavy spring.

K = Sustaining Bleed Operation. Use only with momentary

signal air operator.

3 & 4 Basic Size
01 = 1/4" Basic, (Valve Types D, E, F)

1/2" Basic, (Valve Types A, B, C)

02 = 1/2" Basic, (Valve Types C, D, E, F, G)

1"

Basic, (Valve Types A, B)

03 = 1"

Basic, (Valve Types C, D, E, F, G)

2"

Basic, (Valve Type A)

04 = 1"

Basic, (Valve Types D, E)

2"

Basic, (Valve Type C)

05 = 1/2" Basic, (Valve Type C with 1/4", 3/8" & 1/2" ports)
06 = 1/2" Basic, (Valve Type C with 3/4" port)
07 = 1/2" Basic, (Valve Type D with indicator pin)
08 = 1"

Basic, (Valve Type D with indicator pin)

2"

Basic, (Valve Type C)

21 = 1/2" Basic, (Valve Type F, Valve with subbase)
22 = 1"

Basic, (Valve Type F, Valve with subbase)

23 = 1/2" Basic, (Valve Type F, Valve without subbase)
24 = 1"

Basic, (Valve Type F, Valve without subbase)

Valve Body

Operator

Time

Delay

2

1

3

7 8

9 10

6

-

4 5

-

Advertising