Prospector series poppet valves – Norgren Prospector Series Datasheets User Manual

Page 41

Advertising
background image

Prospector Series Poppet Valves

Littleton, CO USA

Phone: 303-794-2611

www.norgren.com

VAL-12-41

Manual & Mechanical Operated Inline & Subbase Valves

Options Information

For optional features, note the valve model number that comes closest to the desired valve from the preceding order table. Change the model

number as shown in the following diagram to obtain the desired option. For example: the ordering table on VAL12-37 shows D1022C-00-MB, a

3-port/2-position valve with a palm button operator with spring return. To use this valve with a lever, horizontal detented operator, change the last two

digits to MD, as shown below. To order operators with fluorocarbon elastomers, please contact Technical Services.

§ Repair Kit: Kits are available for the above operators. For nitrile order:

53769 - 01.

To calculate the weight of a valve and optional operator take the weight given for the relevant valve from the ordering tables, subtract 0.87 lbs (0.40 kg) for
an MB operator and add the weight given above for the appropriate optional operator.

For example: For D1022C-00-MB has a listed weight of 2.38 lbs (1.08 kg). To convert this from a palm button operator to a foot pedal, vertical operator, i.e.
D1022C-00-MM

1.08 - 0.47 + 4.17 = 4.78 kg (10.53 lbs.)

D

1

0

2

2

C

0

0

M

B

Position in Model Number

1

2

3

4

5

6

7

8

9

10

J

Vacuum Service†

Operator Options§

Weight

Operating Forces

lbs. (kg)

lbs (kg.)

M B

Palm Button,

0.87 (0.40)

6.0 (2.7)

Spring Return

M C

Lever Horizontal,

0.93 (0.42)

1.5 (0.7)

Spring Return

M D

Lever Horizontal,

0.93 (0.42)

To open: 2.3 (1.0)

Detented

To close: 1.5 (0.7)

M J

Roller Horizontal,

1.20 (0.55)

1.8 (0.8)

Spring Return

M K

Roller Vertical,

1.20 (0.55)

2.5 (1.1)

Spring Return

M M

Foot Pedal, Vertical

9.19 (4.17)

4.0 (1.8)

Spring Return

Example model number is a 3-port/2-position (3-way) valve
with a palm button operator and a spring return.

Vacuum Service

For on-off application of vacuum, use a

normally closed 2-port/2-position (2-way) valve.
When the valve is actuated, vacuum will be
applied to the outlet port.

For selecting alternately between vacuum and

pressure, use a normally open 3-port/2-position
(3-way) valve. Connect the vacuum to the exhaust
port and pressure to the inlet port. When the
valve is actuated, vacuum will be applied to the
outlet port.

For selecting alternately between vacuum and

vent, use a normally open 3-port/2-position (3-
way) valve. Connect the vacuum to the exhaust
port and vent the inlet port. When the valve is
actuated, vacuum will be applied to the outlet
port.

In addition, a 4-port/2-position (4-way) valve

can be connected the same way as 3-port/2-
position (3-way) valves for selecting alternately
between vacuum and pressure or vacuum and
vent. That is, connect the vacuum to the exhaust
port and pressure or vent to the inlet port. When
the valve is actuated, the cylinder ports (outlets)
will be alternately switched between vacuum and
pressure or vacuum and vent.