FIT-3-28

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

Function Fittings and Flow Controls

Compact units

Easy tube insertion for rapid assembly of
pneumatic circuits

Positive tube retention

Simplifies pneumatic systems

Eliminates need for electrical reed switches

Exhausts on signal side (port 2)

Pressure Sensor Fitting

Inch and Metric

Technical Data

Fluid: Compressed air, nitrogen, inert and non-combustible gases

compatible with materials of construction.
Note:

For other types of fluids or compressed gases, please

consult factory.

Operating Pressure:

Cylinder pressure (Pc)

145 psi (10 bar) max

Sensor supply pressure

43 to 145 psi (3 - 10 bar)

Sensor switch pressure

14.5 psi (1.0 bar) typical

Operating Temperature:

0° to 175°F (–20° to +80°C)

Body Ports

5⁄32'' O.D. tube Push-in
4mm O.D. tube Push-in
1⁄8, 1⁄4 NPTF Banjo Bolt
1⁄8, 1⁄4 ISO G Banjo Bolt

Tube Sizes

5⁄32'' O/D

4mm O/D

Tubing Types:

Nylon 11 or 12, polyurethane (95 durometer or above)
and LPDE (Low Density Polyethylene)

Materials

Body, swivel fitting and collet: Nickel plated brass

O-ring: Silicone free Nitrile

Sealing washer (parallel male threads): Thermoplastic

Tubing: Nylon 11 or 12, Polyurethane (95 durometer or above) and LDPE

(Low Density Polyethylene).

Note: Lower durometer polyurethane may be used, however, an internal

tube support is required to prevent internal collapse of the tube wall.

Ordering Information

To order, quote appropriate product number from
the tables on the following pages.

Product numbering system is designed to make
identification and selection simple:

124GD

124GD

1

2

_

_

_

_

_

_

_

Series
Number

Type

Shape

Tube Size/
Thread Size

Thread Size/
Tube Size

2

1

Advertising
This manual is related to the following products: