Function fittings and flow controls, General information – Norgren Flow Controls User Manual

Page 31

Advertising
background image

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

FIT-3-31

Function Fittings and Flow Controls

Dimensions in Inches (mm)

Model

T70A1800

T70C1800

T70A2800

T70C2800

T70A3800

T70C3800

T70A4800

T70C4800

C/511*

A

1⁄8 NPT

G1/8

1⁄4 NPT

G1/4

3⁄8 NPT

G3/8

1⁄2 NPT

G1/2

1/20 - 3/4

ØB

0.75 (19)

0.75 (19)

0.75 (19)

0.75 (19)

1.18 (30)

1.18 (30)

1.18 (30)

1.18 (30)

C A/F

0.75 (19)

0.75 (19)

0.75 (19)

0.75 (19)

1.18 (30)

1.18 (30)

1.18 (30)

1.18 (30)

D

1.10 (28)

1.10 (28)

1.10 (28)

1.10 (28)

1.57 (40)

1.57 (40)

1.57 (40)

1.57 (40)

2.0 (50)

E A/F

1.18 (30)

1.18 (30)

1.18 (30)

1.18 (30)

1.81 (46)

1.81 (46)

1.81 (46)

1.81 (46)

1.87 (47.5)

F

0.60 (15.3)

0.60 (15.3)

0.60 (15.3)

0.60 (15.3)

0.61 (15.5)

0.61 (15.5)

0.61 (15.5)

0.61 (15.5)

G

0.14 (3.5)

0.14 (3.5)

0.14 (3.5)

0.14 (3.5)

0.16 (4)

0.16 (4)

0.16 (4)

0.16 (4)

H

2.09 (53)

2.09 (53)

2.09 (53)

2.09 (53)

2.89 (73.5)

2.89 (73.5)

2.89 (73.5)

2.89 (73.5)

3.38 (86)

ØJ

1.14 (29)

1.14 (29)

1.14 (29)

1.14 (29)

1.81 (46)

1.81 (46)

1.81 (46)

1.81 (46)

K

1.40 (35.5)

1.40 (35.5)

1.40 (35.5)

1.40 (35.5)

1.89 (48)

1.89 (48)

1.89 (48)

1.89 (48)

2.72 (69)

General Information

Quick Exhaust Valve

Model

Inlet port

Outlet port

Exhaust port

Cv Flow Factor

Cv Flow Factor

Weight

Repair kit

NPT

ISO G

Direction 1 - 2*

Direction 2 - 3

oz (kg)

(seals only)

T70A 1800

T70C 1800

1⁄8

1⁄8

1⁄8

0.9

1.8

5.3 (0.15)

T70C1800K0

T70A 2800

T70C 2800

1⁄4

1⁄4

1⁄4

1.9

2.5

4.6 (0.13)

T70C2800K0

T70A 3800

T70C 3800

3⁄8

3⁄8

3⁄8

3.8

5.5

7.4 (0.21)

T70C3800K0

T70A 4800

T70C 4800

1⁄2

1⁄2

1⁄2

5.3

5.9

6.7 (0.19)

T70C4800K0

C/511

S/511

1/2

3/4

3/4

**1.9/5.1

10.8

11.0 (0.31)

QS/511/00

* Flow factor measured at 87 psi (6 bar) (inlet) guideline direction

** Alternative Cv shown for 14.5 psi (1 bar). For T70 Series, Cv approximately the same as at 6 bar.

NPT threads per ANSI B1.20.1

E A/F

ØB

C A/F

C A/F

ØJ

K

F

A

H

D

A

A

G

Po

rt

2

Port 1

Port 3

0

(1) (2) (3) (4) (5) (6) (7) (8)

(9) (10)

Inlet Pressure

Chok

ed Flo

w

2-3 Way

1-2 Way

1/2"

2-3 Way

1-2 Way

2-3 Way
1-2 Way
2-3 Way

1-2 Way

}

}

3/8"

}

1/4"

}

1/8"

84

168

252

336

420

504

588

14.5

44

73

102

131

2-3 Way 3/4"

(40)

(80)

(120)

(160)

(200)

(240)

(280)

29

58

87

116

145 psi

(bar)

(dm3/s) scfm

T70 Series Flowrate
Choked flow versus inlet pressure
(1 - 2) + (2 - 3)

* Note the shape of the C/511 is different. Consult our technical department for the exact specifications.

Advertising
This manual is related to the following products: