Function fittings and flow controls – Norgren Flow Controls User Manual

Page 30

Advertising
background image

FIT-3-30

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

Function Fittings and Flow Controls

● Enables air to be exhausted quickly from air

reservoirs and cylinders

● Allows higher cylinder speeds to be achieved

● Simple, compact design and construction

● Reliable operation

T70 Series Quick Exhaust Valves

Technical Data

Fluid:

Compressed air, filtered, lubricated and non-lubricated

Operation:

Diaphragm

Mounting:

Line mounted

Port Size:

Female Thread

(Inlet, outlet and exhaust ports)

NPT

ISO G

1⁄8 NPT T70A1800

G1⁄8

T70C1800

1⁄4 NPT T70A2800

G1⁄4

T70C2800

3⁄8 NPT T70A3800

G3⁄8

T70C3800

1⁄2 NPT T70A4800

G1⁄2

T70C4800

3/4 NPT C/511*

* Note: C/511 has 1/2" NPT inlet port and 3/4" NPT outlet ports.

Operating Pressure:

7 - 145 psi (0.5 - 10 bar)

Operating Temperature:

0° to 175°F (-20°** to +80°C)
**Consult our Technical Service for use below 35°F (2˚C)

Materials
Zinc or aluminum alloy body and cover, nitrile seals (PU seal on C/511).

Ordering Information

To order, quote model number from page FIT-3-21,
e.g. T70A2800 for the NPT ported version. This
range replaces the C/510 and S/510 models.

1

2

3

Quick Exhaust Valve

Typical Fill and Exhaust Times (seconds)

Model

Port

Volume

Fill Exhaust

size

time

time

T70A1800

1/8'' NPT

150 cc

0.036

0.021

T70A2800

1/4'' NPT

150 cc

0.023

0.017

T70A3800

3/8'' NPT

1500 cc

0.110

0.080

T70A4800

1/2'' NPT

15,000 cc

0.460

0.480

C/511

3/4'' NPT

15,000 cc

0.480

0.250

Note: Fill time is 0 to 80 psig (0 to 5.5 bar), and exhaust
time is 101 to 20 psig (7.0 to 1.4 bar)