Operating instructions

13

6.3

Heating and cooling mixing cycles

The total cycle lasts approximately 90…100 minutes and varies according to the mix-
ture quantity, type and thickness.

High heating and cooling mixing cycle

This is a high temperature thermic cycle, devised for those ingredients requiring such
procedure. The machine heaths the mixture to the required temperature [Ta] (between
80°C / 176 °F and 90°C / 194 °F), then chills it to the required Preservation Temperature
[Tca].

Low heating and cooling mixing cycle

This is a lower temperature but extended thermic cycle, devised for delicate ingredients.
The machine heaths the mixture to the required temperature [Tb] (between 60°C / 140
°F and 70°C / 158 °F) and maintains this temperature for 30 minutes. The mixture is
then chilled to the required Preservation Temperature [Tcb].

6.4

Setting Up

The machine has been adjusted during testing with optimal settings. Do not modify settings unless
strictly necessary.

Note:

Set up the machine when not in function, before starting production.

-

Press ON/OFF [K1], the machine is now on. Press SET UP [K8]. On the display “P1” will flash, showing that you are
now in SET UP mode and can proceed to set up the required temperature for the High heating and cooling mixing
automatic cycle;

Note:

If you wait longer than 7…8 seconds without pressing any pushbutton, any new setting will be automatically stored
and the SET UP mode will terminate.

-

press SET UP [K8] again. The display shows the High heating and cooling mixing temperature [Ta]. If required, adjust
temperature by pressing ADJUSTMENT [K2] or [K3]. The manufacturer’s settings is +85°C. The adjustment range is
+80°C…+90°C;

-

press SET UP [K8] again. The display shows the preservation temperature at the end of the automatic High heating and
cooling mixing cycle [Tca]. If required, adjust temperature by pressing ADJUSTMENT [K2] or [K3]. The manufacturer’s
setting is +4°C (39 °F). The adjustment range is +1°C (34 °F)…+6°C (43 °F);