2 device’s parts reassembling, 3 electrical connection – Vollrath Mix30 User Manual

Page 8

Advertising
background image

English

Mixer

8

5.2

Device’s parts reassembling

-

Before inserting the tap, turn the lever [15] fully to the LEFT (OPEN position). Failing to do so might prevent the tap
from fully inserting in the slot;

-

Ease (do not fully unscrew it) knurled fastening knob [16];

-

If necessary, lubricate the piston’s end [13], inside the slot [3], and their gaskets, with food-compatible grease (i.e.
vaseline);

-

Fully insert [11] into the slot [3] and tighten fastening knob [16];

Check that the knob’s head [16] is correctly and firmly fixed in the slot [3], as to avoid damage to the
gaskets and subsequent leakages.

-

Turn tap’s lever fully to the RIGHT (CLOSED position). Check that there is no excessive strain on the part.

-

Install drip tray [26] (with its bracket [27]) onto the front panel.

5.3

Electrical connection

THE SUPPLY’S VOLTAGE REQUIRED BY THE DEVICE IS HIGH, SO, IT IS PARTICULARLY DANGEROUS.
THE WORKS ON THE SUPPLY’S ELECTRIC CIRCUITS MUST BE MADE WORKMANLIKE BY QUALIFIED
STAFF.

THE ELECTRIC SAFETY OF THIS AUTOMATIC DEVICE IS REACHED ONLY
WHEN THE SAME IS CORRECTLY CONNECTED, BY QUALIFIED AND
CERTIFIED PERSONNEL, TO AN EFFICIENT EARTHING SYSTEM, MADE
AS PROVIDED FOR IN FORCE SAFETY REGULATIONS.

The manufacturer must not be considered responsible for eventual damages
caused by an inadequate electric or earthing system.

All the electric device's features required for the system’s proportioning are reported on
the Technical Data Plate and on the Technical Handbook.

FOR PREPARING THE ELECTRIC SYSTEM WHICH SUPPLIES THE DEVICE, IT IS COMPULSORY TO FOL-
LOW THE PRESCRIPTIVE STANDARDS IN FORCE. IN PARTICULAR:

-

The electric capacity of the system must exactly match the supply’s voltage and frequency required by the device;

-

the current capacity of the system must be suitable for the device’s input;

-

the system must end with an accepted 4 pole electric socket and with electric and mechanical suitable characteristics.
The electric socket’s poles must be marked with appropriate letters (phases R-S-T + earth); the earth’s pole must be
recognizable;

-

the electric socket must prevent, through appropriate mechanical measures, the plug’s wrong connection;

-

the electric socket must have, above or annexed, a breaker, conformed to the in force safety laws, with an associated
gearing placed near the device, in a position easily reachable by the operator. It must also be protected by fuses, above
or annexed, with characteristics suited at the current absorbed by the device.

A WRONG CONNECTION ON THE EARTH TERMINAL MAY CAUSE SERIOUS DANGER.

Advertising