Vollrath Mix30 User Manual

Page 21

Advertising
background image

English
Operating instructions

21

UNUSUAL NOISINESS.

The noise comes mainly from the tank, when beating is on.

Cause:

There are solids or heavy sediments inside the tank or on the beater. Stop the machine, wait
until mixture has cooled down, empty the tank and remove them.

The beater’s motor is damaged. Call Assistance Service.

The noise does NOT come from the tank, but is heard even when no beating is on.

Cause:

Inside break down. Call the Assistance Service.

ALARM CODE

The Display shows an alarm code P – – / PEE

TAKE THE POWER SUPPLY OFF at once by the Main Breaker.

Note:

Alarm signals are unusual but possible under special circumstances. Before deciding that machine is out
of order, switch machine off for as long as it takes to normalize temperatures (30...60 minutes), turn back
on and check for alarm signals.

Alarm code “P – –”: the TANK's temperature probe detects a temperature HIGHER than the safety limits.

Note: If a very high TEMPERATURE is programmed (see par. 6.3, P1 programming) the alarm may go

ff (this occurs, however, only in certain circumstances). Cause: Machi

e is running dry or product in the tank is insufficient. Restore minimum quantity of product.

Cause: The tank temperature probe is broken (interrupted or out of tolerance range). Call Assistance Service.

Alarm code “PEE”: the TANK's temperature probe detects a temperature LOWER than the safety limits.

Cause:

The tank temperature probe is broken (due to a short circuit) or wiring is damaged. Call Assistance
Service.

Cause:

The control circuits can't take the power supply off to the compressor (it is kept on). Relevant power relay
has likely locked. Call the Assistance Service.

Cause:

The tank temperature probe is broken (cut off or out of range). Call Assistance Service.

Advertising