10 m – Vollrath Mix30 User Manual

Page 19

Advertising
background image

English
Operating instructions

19

9

P

ERIODS OF INACTIVITY

If long periods of inactivity are foreseen, proceed as follows:

-

wash up completely the device (see Chapter 7);

-

switch off the socket's breaker and unplug the device;

-

check that the Main Breaker is on the “0” position;

-

close the water faucet and relieve pressure from inside the delivery pipe by unscrewing one of the pipe fittings.
Remove both delivery and drain pipes and let all water out. Before using the pipes again, following a long period of
inactivity, check for any damages or cracks and replace, if necessary, pipe fittings’ gaskets.

-

if the device will be stored in a different place, group all the documentation, together with the present manual, and
enclose it at the device (for example inside the tub).

Before storing the device in rooms with a temperature lower to 0°C (32°F) it is INDISPENSABLE to get rid
of the water in the condensator (with WATER condensation) and in the inlet, outlet and washing pipes.
Call the Assistance Service.

10 M

ALFUNCTIONS

WE RECOMMEND YOU TO CALL IMMEDIATELY THE ASSISTANCE SERVICE IF A MALFUNCTION DIF-
FERENT FROM THOSE HERE DESCRIBED IS FOUND.

Note:

the following malfunctions do not refer to problems noticed in the installation phase, but ONLY on correctly
installed - and already functioning - devices.

THE DEVICE DOES NOT SEEM TO BE WORKING AT ALL.

With the Main Breaker on 1 the ON/OFF indicator [Z1] DOES NOT TURN ON.

Cause:

The plug is not correctly plugged.

The socket is defective. A qualified technician should substitute it.

Power in the socket is missing. Check that the Main Switches, the breakers and the differen-
tials (lifesavers) on the electric plant are closed. If they aren’t, before closing them, make sure
that no one is making electrical maintenance.

A protective fuse of the electric plant is cut down. Find and eliminate the eventual cause of
overcharge. Substitute cut down fuses with others of the same kind.

The supply cable is defective. BEFORE, cut down electrical feeding at the socket by opening
the breaker above it, then disconnect the plug and call the Assistance Service.

DO NOT TOUCH THE DAMAGED ELECTRICAL CABLES BEFORE HAVING CUT DOWN
THE ELECTRICAL SUPPLY!

With the Main Breaker on 1 the ON/OFF indicator [Z1] TURNS ON, but the display shows 3 small squares
and the device does not work.

Cause:

The lid is not correctly closed or tends to open;

The lid’s magnet is damaged. Call the Assistance Service.

The lid magneto has been positioned incorrectly. Call the Assistance Service

THE MAGNETIC CONTACT AND THE RELATIVE MAGNET ARE IMPORTANT SAFETY
DISPOSALS!