3 sanitizing – Vollrath Mix30 User Manual

Page 17

Advertising
background image

English
Operating instructions

17

-

Turn lever [15] to the LEFT to open tap;

-

ease knurled fastening knob [16] and remove tap from slot [3];

-

remove lever [15] and remove cover [14];

-

remove piston [13] from tap’s inner body [12];

-

remove gaskets [G] (see Par. 8.1);

-

Each component mentioned in points 6-7 must be washed using a suitable brush in a solution consisting of 2 oz of
detergent suitable for use with food preparation equipment in 2 gallons of hot water (104°F). Rinse each part using water
at room temperature.

Note: The gaskets must be periodically replaced (ref. Par. 8.1).

7.3

Sanitizing

-

Prepare a solution consisting of 2 oz of Spartan Chemical SANI-T-10 disinfectant in 2 gallons of water at room tempera-
ture. Immerse all the components mentioned in Par. 7.2 in this solution for 5 minutes.

-

Remove the components from the solution; lubrificate the seals and the inner surfaces of the tap joint using grease
suitable for use with food preparation equipment. Re-asemble all the sanitized parts in their original positions.

-

Pour a solution consisting of 2 oz of Spartan Chemical SANI-T-10 disinfectant in 2 gallons of water at room temperature
into the tank. Clean all the tank surfaces and the lid, using disposable sterile material or suitable brush. Press the stir
button and allow the machine to run for 5 minutes before emptying the tank.

-

Rotate the spillage collector to one side, position a container under the tap and open it to empty the tank.

-

The machine should be rinsed first with a disinfectant solution and then with the drinking water, ensuring that the correct
hygiene procedures are observed, in accordance with national or local regulations.

-

Each time the machine is cleaned, it must be sanitized, using sterile gloves. Sanitization must be carried out on a
regular basis, in accordance with local hygiene regulations.

8

M

AINTENANCE

The device requires a very limited maintenance. Periodically, we suggest to:

-

check the good state of the parts of the device. The disassembly, for example during the accurate washing, is an ideal
opportunity for a similar check (ref. Par. 8.1);

-

check that electric power cable, pipe fittings (rubber holder) and water pipes are not damaged;

-

Try the efficiency of the safety disposals (ref. Par. 8.2).

It is then useful to maintain the external panels clean and the surrounding area. Dust, paper fragments or other small objects
may penetrate in the device through the ventilation loopholes (in particular if equipped with air condensation and rapidly
compromise its correct functioning.

The inside parts, to which the user MUST NOT accede, must be checked by the Assistance Service (ref. Par. 8.3)