Diagnostic Error Code

FRU/Action

014-199-XXX Parallel port test failed, cause unknown

1. Go to “Undetermined problems” on page 76.

2. Flash the system and re-test. See “Flash update

procedures” on page 127.

3. Replace component under function test.

014-2XX-XXX 014-3XX-XXX Parallel port failure

1. External parallel device

2. System board

015-000-XXX USB port Interface Test Passed

No action

015-001-XXX USB port Presence

1. Remove USB device(s) and re-test.

2. System board

015-002-XXX USB port Timeout

1. Remove USB device(s) and re-test.

2. System board

015-015-XXX USB port External Loopback failure

1. Remove USB device(s) and re-test.

2. System board

015-027-XXX USB port Configuration/Setup error

1. Flash the system. See “Flash update procedures”

on page 127.

2. System board

015-032-XXX USB port Device Controller failure

System board

015-034-XXX USB port buffer allocation failure

1. Reboot the system

2. Flash the system and re-test. See “Flash update

procedures” on page 127.

3. Run memory test.

4. System board

015-035-XXX USB port Reset condition detected

1. Remove USB device(s) and re-test.

2. System board

015-036-XXX USB port Register error

System board

015-040-XXX USB port IRQ failure

1. Run the Setup Utility program and check for

conflicts.

2. Flash the system. See “Flash update procedures”

on page 127.

3. System board

015-195-XXX USB port Test aborted by user

Information only Restart the test, if necessary.

015-196-XXX USB port test halt, error threshold exceeded

1. Press F3 to review the log file.

2. Restart the test to reset the log file.

015-197-XXX USB port test warning

1. Make sure the component that is called out is

connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 51
.

2. Re-run test.

3. Replace the component that is called out in warning

statement.

4. Replace the component under test.

Chapter 7

.

Symptom-to-FRU Index

63