64

HW Diagnostics

NPX TEST

* Meaning of Details Information (DETAILS = XXXXXXXXXXXXXXXX)

AA BB CC DD EEEE FFFF

AA

:

Host and Channel number that the hard disk drive is connected to.

BB

:

Driver completion status

CC

:

ASPI status

DD

:

Host status

EEEE

:

Sense data

FFFF

:

Sense code

[07. NPX TEST]
This tests the computer's floating data processing unit functions.

[01. NPX test]
This test checks the Addition and Multiplication functions of the coprocessor.

NPX TEST (NPX) Error log

Status

Error name

Meaning

01

NO CO-PROCESSOR

Co-processor recognition error

02

CONTROL WORD ERROR

Set control word error

03

STATUS WORD ERROR

Status word error

04

BUS ERROR

BUS error

05

ADDITION ERROR

Addition test error

06

MULTIPLICATION ERROR

Multiplication test error

07

EXCEPTION ERROR

Exception error

[08. CACHE MEMORY TEST]
To test the L2 caching unit.

CACHE MEMORY TEST (CAH) Error log

Status

Error name

Meaning

01

MEMORY PARITY ERROR

Memory parity error

02

PROTECT MODE ERROR

The shift to the protected mode failed.

03

CACHING ERROR

An error occurred on the cache system.

FF

DATA COMPARE ERROR

Data comparing error

[09. SCSI TEST]
To test the SCSI devices.
Before running the test, the parameters must be set. If "HOST ID NUMBER" is set to "ALL",
the " SCSI ID NUMBER" and "CHANNEL NUMBER" are ignored.

[01. INQUIRY]
This subtest issues the INQUIRY command to the SCSI bus and displays the results of
the messages returned from the devices on the SCSI bus. After specifying the valid host
and channel number, the INQUIRY command is sent to the target SCSI bus. It then
displays the result code from ID0 through ID15.