Configure the following connection details in the, View of the, Window – Barracuda Networks VERSION SP4 User Manual

Page 48

Advertising
background image

46 Server Config – Personal Firewall Rules

Configure the following connection details in the

Advanced

view of the

Rule Object

window:

Modifying an object is a global action. For example, any other rule using the specific object will be affected by the mod-
ification.
This applies only for referenced objects, not for objects of type <explicit>.
Explicit objects are only available for the current rule.

Table 3–2

Edit/Create Rule Object – Sections

Section

Description

Adapter

Specify an adapter for the connection request. In the list all

Adapter Objects

that have been defined in the

Adapter

window are

available (3.3 Adapters, page 51).
Right-click the adapter window below the list and Select

New …

to create a new Adapter Object.

Double-click an available entry to edit the assigned Adapter Object.

Source /
Destination

Specify a source for the connection request. In the list all

Network Objects

that have been defined in the

Networks

window are

available (3.5 Net Objects, page 55).
Select

<Explicit>

to define a network object explicitly without adding it to the Network Objects listing.

Right-click the source window below the list and Select

New …

to create a new Network Object.

Double-click an available entry to edit the assigned Network Object.

Service

Specify a service for the connection request. In the list all

Service Objects

that have been defined in the

Services

window are

available (3.6 Service Objects, page 58).
Select

<Explicit>

to define a network object explicitly without adding it to the Service Objects listing.

Right-click the source window below the list and Select

New …

to create a new Service Object.

Double-click an available entry to edit the assigned Service Object.

Application

(optional)

Specify an application for the connection request. In the list all

Application Objects

that have been defined in the

Application

window are available (3.7 Application Objects, page 59).
Select

<Explicit>

to define an application object explicitly without adding it to the Application Objects listing.

Right-click the source window below the list and Select

New …

to create a new Application Object.

Double-click an available entry to edit the assigned Application Object.

User

(optional)

Specify an user for the connection request. In the list all

User Objects

that have been defined in the

User

window are available

(3.4 User Objects, page 54).
Select

<Explicit>

to define an user object explicitly without adding it to the User Objects listing.

Right-click the source window below the list and Select

New …

to create a new User Object.

Double-click an available entry to edit the assigned User Object.

List 3–2 Edit/Create Rule Object - Options in the Advanced view – section Rule Mismatch Policy

Parameter

Description

Source /
Service/
Destination /
Application /
User / Adapter

• Continue on Mismatch (default)

Process the rule, even if the corresponding object does not match the configured setting.

• BLOCK on Mismatch

Do not process the rule if the corresponding object does not match the configured setting.

List 3–3 Edit/Create Rule Object - Options in the Advanced view – section Miscellaneous

Parameter

Description

Time Restriction

A time restriction can be assigned to each rule. The granularity is 1 hour on a weekly base.
A rule is allowed at all times by default, for example, all checkboxes in the

Time Interval

window are cleared. Selecting a checkbox

denies a rule for the given time.
Select

(set invert) from the list to configure allowed and disallowed time intervals simultaneously.

Select

(set allow) from the list to clear selected checkboxes.

Select

(set deny) from the list to to configure disallowed time intervals.