SPECIFICATIONS

Input Characteristics

TRIG IN

External trigger to initiate delay and width sequences.

Range:

0-100 MHz.

Input Impedance:

50 ohms.

Slope:

Selectable pos/neg.

Minimum Pulse Width:

3 ns.

Minimum Signal Amplitude: 100 mV.
Maximum Signal Amplitude: ± 7 V.
Threshold Range:

± 2.5 V.

Threshold Resolution:

10 mV.

Trigger Jitter:

20 ps rms (between TRIG IN and TRIG OUT).


MODULE DISABLE

Allows the outputs on some modules to be remotely
disabled.

Disable:

4 V - 5 V. 5 mA sourcing current (into the 6040) or
contact opening.

Enable:

0 - 300 mV, 5 mA sinking current (from the 6040)
contact closure, or plug removed from jack.


Output Characteristics


PULSE OUT

Provides the signal selected by the rep rate,
delay, width, and single/ double pulse settings.
Corresponds in timing to ECL OUT and to module outputs.


Amplitude:

+5 V into 50 ohms.

Transition Times:

1 ns rise time, 1.5 fall time.

Insertion Delay:

50 ns typical (between TRIG IN and PULSE OUT;

see Figure 1-1).

ECL OUT

Provides an ECL version of PULSE OUT.


Amplitude:

-0.8 V to -1.8 V into 50 ohms ("low true" pulses).

Transition Times:

700 ps.

Insertion Delay:

50 ns typical (between TRIG IN and ECL OUT; see

Figure 1-1).