PERFORMANCE DATA

COOLING EXTENDED PERFORMANCE TABLE

HEATING EXTENDED PERFORMANCE TABLE

-10–20

HEATING EXTENDED PERFORMANCE TABLE 30–60

*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 17.

602A024 (2 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

700/0.02

800/0.02

900/0.05

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

26.3

24.2

22.3

21.9

26.5

24.5

2.3

22.4

26.6

24.6

22.9

23.0

SHC

13.0

16.7

16.0

19.9

13.6

17.7

1.7

21.2

14.0

18.6

17.9

22.3

kW

1.9

1.9

1.9

1.9

2.0

2.0

2.0

2.0

2.1

2.1

2.0

2.0

95

TC

25.6

23.2

21.3

20.9

25.8

23.5

21.6

21.5

25.9

23.7

21.8

22.2

SHC

12.9

16.3

15.6

19.5

13.4

17.3

16.5

20.7

13.9

18.3

17.5

21.5

kW

2.1

2.1

21.1

2.1

2.2

2.2

2.2

2.2

2.3

2.3

2.2

2.2

105

TC

24.6

22.0

20.2

19.9

24.9

22.3

20.5

20.6

25.0

22.5

20.7

21.2

SHC

12.6

15.8

15.1

19.0

13.1

16.9

16.1

20.0

13.7

17.9

16.6

20.6

kW

2.4

2.4

2.3

2.3

2.4

2.4

2.4

2.4

2.5

2.5

2.5

2.5

115

TC

23.4

20.9

19.1

19.0

23.7

21.1

19.4

19.7

23.8

21.3

19.6

20.3

SHC

12.1

15.4

14.7

18.3

12.8

16.5

15.6

19.1

13.3

17.5

15.9

19.6

kW

2.6

2.6

2.3

2.6

2.7

2.7

2.6

2.6

2.8

2.8

2.7

2.7

602A024 (2 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

700

TC

8.56

7.92

10.43

9.59

12.50

11.47

27.90

25.44

15.19

13.78

kW

1.61

1.68

1.75

1.78

1.82

800

TC

8.88

8.21

10.73

9.88

12.82

11.77

14.43

13.15

15.52

14.08

kW

1.68

1.74

1.81

1.83

1.87

900

TC

9.22

8.52

11.07

10.19

13.14

12.06

14.77

13.46

15.87

14.40

kW

1.77

1.82

1.87

1.91

1.95

70

700

TC

8.10

7.49

10.04

9.24

12.15

11.15

13.77

12.56

14.83

13.45

kW

1.73

1.83

1.91

1.96

2.00

800

TC

8.43

7.80

10.35

9.53

12.47

11.44

14.09

12.84

15.17

13.75

kW

1.80

1.89

1.96

2.00

2.04

900

TC

8.91

8.24

10.71

9.85

12.81

11.76

14.43

13.16

15.53

14.08

kW

1.85

1.97

2.04

2.07

2.11

80

700

TC

7.54

6.97

9.58

8.81

11.74

10.77

13.38

12.20

14.46

13.11

kW

1.85

1.97

2.08

2.16

2.19

800

TC

7.94

7.35

9.91

9.12

12.07

11.08

13.74

12.52

14.80

13.42

kW

1.91

2.03

2.13

2.19

2.23

900

TC

8.22

7.60

10.27

9.45

12.43

11.41

14.07

12.83

15.16

13.75

kW

2.01

2.11

2.20

2.27

2.30

602A024 (2 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

700

TC

19.31

16.92

22.77

22.77

25.10

25.10

25.56

25.56

27.03

27.03

kW

1.94

2.07

2.12

2.14

2.17

800

TC

19.50

17.08

22.69

22.69

24.82

24.82

25.37

25.37

26.78

26.78

kW

1.97

2.08

2.13

2.14

2.17

900

TC

19.62

17.20

22.65

22.65

24.81

24.81

25.14

25.14

26.52

26.52

kW

2.03

2.13

2.19

2.19

2.22

70

700

TC

18.89

16.55

23.02

23.02

25.48

25.48

25.96

25.96

27.48

27.48

kW

2.15

2.28

2.38

2.39

2.45

800

TC

19.33

16.94

23.07

23.07

25.42

25.42

25.89

25.89

27.42

27.42

kW

2.18

2.29

2.38

2.38

2.43

900

TC

19.69

17.25

23.09

23.09

25.37

25.37

25.82

25.82

27.11

27.11

kW

2.24

2.35

2.41

2.42

2.46

80

700

TC

18.48

16.19

23.07

23.07

25.68

25.68

26.23

26.23

28.02

28.02

kW

2.38

2.54

2.65

2.68

2.74

800

TC

18.87

16.53

23.30

23.30

25.71

25.71

26.22

26.22

28.87

28.87

kW

2.40

2.53

2.64

2.65

2.70

900

TC

19.28

16.90

23.43

23.43

25.81

25.81

26.26

26.26

27.68

27.68

kW

2.45

2.57

2.67

2.68

2.71

Advertising