602A048 (4 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

1400/0.07

1600/0.07

1800/0.08

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

52.8

48.7

45.2

44.5

53.0

48.9

45.5

45.5

52.9

49.0

45.6

46.4

SHC

25.2

32.5

31.3

39.2

26.0

34.1

33.0

41.2

26.5

35.6

34.5

41.8

kW

4.0

4.0

3.9

3.9

4.2

4.2

4.1

4.0

4.4

4.3

4.3

4.1

95

TC

51.1

46.9

43.0

42.9

51.3

47.1

43.6

44.0

51.2

47.2

43.7

44.9

SHC

24.7

32.0

29.9

38.4

25.5

33.7

32.2

39.8

26.3

35.3

33.6

40.9

kW

4.4

4.4

4.3

4.2

4.6

4.6

4.5

4.3

4.8

4.7

4.6

4.5

105

TC

49.3

44.8

41.3

41.1

49.4

45.0

41.7

42.3

49.3

45.0

41.7

43.3

SHC

24.2

31.3

29.8

37.2

25.1

33.1

31.6

38.4

25.8

34.8

32.9

39.1

kW

4.9

4.8

4.7

4.6

5.1

5.0

4.8

4.7

5.3

5.2

5.0

4.9

115

TC

47.1

42.5

39.2

39.5

47.3

42.7

39.5

40.5

47.2

42.8

39.4

41.3

SHC

23.6

30.5

28.9

35.8

24.5

32.3

30.6

37.2

25.2

34.0

32.1

38.1

kW

5.4

5.2

5.1

5.0

5.6

5.4

5.2

5.2

5.8

5.6

5.4

5.3

602A048 (4 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

1400

TC

13.75

12.72

18.17

16.72

22.58

20.73

27.90

25.44

27.16

24.63

kW

2.60

2.85

3.11

3.29

3.33

1600

TC

14.56

13.47

18.93

17.42

23.29

21.38

26.35

24.02

27.70

25.12

kW

2.97

3.16

3.36

3.49

3.49

1800

TC

15.63

14.45

19.92

18.33

24.21

22.23

27.22

24.82

28.47

25.82

kW

3.21

3.37

3.54

3.65

3.65

70

1400

TC

12.18

11.26

16.85

15.50

21.52

19.75

24.79

22.61

26.48

24.02

kW

2.80

3.10

3.39

3.59

3.65

1600

TC

13.21

12.22

17.80

16.38

22.40

20.56

25.61

23.35

27.15

24.62

kW

2.98

3.23

3.49

3.67

3.71

1800

TC

14.52

13.43

19.01

17.49

23.49

21.56

26.63

24.28

28.14

25.52

kW

3.32

3.53

3.74

3.89

3.91

80

1400

TC

12.79

11.83

18.22

16.77

21.89

20.10

24.67

22.49

25.82

23.42

kW

2.98

3.40

3.66

3.82

3.92

1600

TC

13.91

12.87

18.97

17.45

22.71

20.84

25.37

23.13

27.38

24.84

kW

3.16

3.52

3.74

3.89

4.01

1800

TC

14.60

13.51

19.52

17.96

23.05

21.15

26.58

24.23

28.08

25.46

kW

3.52

3.75

4.04

4.18

4.22

602A048 (4 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

1400

TC

32.14

28.16

37.41

37.41

41.34

41.34

42.95

42.95

47.11

47.11

kW

3.51

3.56

3.73

3.79

4.00

1600

TC

32.85

28.79

38.08

38.08

42.03

42.03

43.43

43.43

47.50

47.50

kW

3.58

3.83

3.71

3.77

3.94

1800

TC

33.66

29.49

39.03

39.03

42.66

42.66

44.04

44.04

48.07

48.07

kW

3.73

3.78

3.82

3.83

3.96

70

1400

TC

31.48

27.58

37.06

37.06

41.24

41.24

42.79

42.79

47.50

47.50

kW

3.82

3.98

4.09

4.17

4.44

1600

TC

32.28

28.29

37.84

37.84

41.89

41.89

43.41

43.41

47.87

47.87

kW

3.84

3.98

4.06

4.14

4.35

1800

TC

33.18

29.08

38.65

38.65

42.65

42.65

44.09

44.09

48.47

48.47

kW

3.98

4.08

4.15

4.21

4.35

80

1400

TC

30.84

27.03

36.31

36.31

40.68

40.68

42.36

42.36

47.65

47.65

kW

4.12

4.43

4.49

4.61

4.90

1600

TC

32.48

28.46

37.20

37.20

41.55

41.55

42.96

42.96

48.21

48.21

kW

4.18

4.31

4.43

4.51

4.81

1800

TC

33.19

29.08

38.12

38.12

42.37

42.37

43.55

43.55

48.77

48.77

kW

4.33

4.42

4.50

4.52

4.81

Advertising