PERFORMANCE DATA

COOLING EXTENDED PERFORMANCE TABLE

HEATING EXTENDED PERFORMANCE TABLE

-10–20

HEATING EXTENDED PERFORMANCE TABLE 30–60

*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 17.

602A060 (5 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

1750/0.07

2000/0.12

2250/0.15

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

67.9

61.8

56.5

55.5

68.9

63.3

57.9

57.2

69.6

64.4

59.1

59.0

SHC

35.1

44.4

42.2

52.5

36.8

47.7

45.2

56.4

38.4

50.7

48.2

59.0

kW

5.25

5.22

5.16

5.15

5.27

5.22

5.19

5.18

5.28

5.22

5.22

5.22

95

TC

65.3

59.0

53.4

52.5

66.5

59.8

54.7

54.3

67.3

61.1

55.8

56.3

SHC

34.3

43.3

40.8

50.9

36.2

46.1

43.8

54.3

38.0

49.5

46.7

56.3

kW

5.78

5.74

5.63

5.61

5.78

5.77

5.66

5.66

5.79

5.76

5.69

5.70

105

TC

62.8

55.2

50.5

49.5

64.0

57.1

51.5

51.6

64.1

57.5

52.5

53.7

SHC

33.6

41.5

39.7

49.4

35.6

45.3

42.4

51.6

36.9

47.9

45.3

53.7

kW

6.34

6.27

6.21

6.14

6.36

6.32

6.18

6.19

6.35

6.35

6.21

6.24

115

TC

58.7

52.3

46.9

47.1

59.9

53.1

48.1

49.0

60.7

54.1

49.4

50.9

SHC

31.8

40.6

38.0

47.1

33.9

43.4

40.9

49.0

35.8

46.5

44.3

50.9

kW

6.94

6.78

6.72

6.64

6.95

6.90

6.75

6.77

6.96

6.94

6.69

6.82

602A060 (5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

1750

TC

22.7

21.0

27.8

25.6

33.3

30.5

36.6

33.4

39.4

35.7

kW

3.82

4.08

4.15

4.21

4.27

2000

TC

23.2

21.4

28.5

26.3

33.5

30.9

36.8

33.6

40.0

36.3

kW

3.81

3.94

4.12

4.17

4.21

2250

TC

23.4

21.6

28.6

26.3

33.8

31.1

37.2

33.9

40.5

36.7

kW

3.79

3.92

4.04

4.10

4.15

70

1750

TC

21.1

19.5

26.4

24.3

32.8

30.1

35.8

32.6

38.8

35.2

kW

4.02

4.27

4.48

4.55

4.63

2000

TC

21.3

19.7

27.3

25.1

32.9

30.2

36.0

32.8

39.1

35.5

kW

4.01

4.26

4.42

4.49

4.57

2250

TC

21.5

19.9

28.4

26.1

33.1

30.4

36.2

33.0

39.3

35.7

kW

4.00

4.21

4.49

4.49

4.50

80

1750

TC

18.1

16.7

21.1

19.4

32.2

29.5

35.1

32.0

38.0

34.4

kW

4.12

4.48

4.83

4.94

5.05

2000

TC

18.3

16.9

22.7

20.9

31.9

29.3

34.9

31.8

38.0

34.4

kW

4.11

4.47

4.77

4.88

4.98

2250

TC

18.5

17.1

25.4

23.4

30.8

28.3

35.1

32.0

39.3

35.7

kW

4.11

4.48

4.69

4.82

4.95

602A060 (5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

1750

TC

46.1

40.4

52.8

52.8

57.7

57.7

59.4

59.4

64.8

64.8

kW

4.39

4.57

4.62

4.66

4.79

2000

TC

46.7

40.9

53.0

53.0

57.5

57.5

59.1

59.1

64.1

64.1

kW

4.35

4.41

4.50

4.53

4.64

2250

TC

46.7

40.9

52.9

52.9

57.3

57.3

58.6

58.6

63.3

63.3

kW

4.27

4.32

4.41

4.43

4.53

70

1750

TC

45.3

39.7

52.5

52.5

57.2

57.2

59.3

59.3

65.0

65.0

kW

4.81

5.04

5.05

5.09

5.24

2000

TC

45.8

40.1

52.5

52.5

57.3

57.3

59.3

59.3

64.5

64.5

kW

4.76

4.93

4.92

4.96

5.08

2250

TC

45.8

40.2

52.3

52.3

57.4

57.4

59.1

59.1

64.1

64.1

kW

4.65

4.82

4.82

4.85

4.96

80

1750

TC

44.2

38.8

51.2

51.2

56.1

56.1

58.6

58.6

65.0

65.0

kW

5.21

5.51

5.56

5.57

5.73

2000

TC

44.2

38.8

52.1

52.1

56.5

56.5

58.8

58.8

64.9

64.9

kW

5.09

5.39

5.40

5.43

5.57

2250

TC

44.3

38.8

51.6

51.6

56.7

56.7

58.9

58.9

64.7

64.7

kW

4.87

5.32

5.29

5.32

5.45

Advertising