PERFORMANCE DATA (cont)

COOLING EXTENDED PERFORMANCE TABLE

HEATING EXTENDED PERFORMANCE TABLE

-10–20

HEATING EXTENDED PERFORMANCE TABLE 30–60

*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 17.

602A042 (3.5 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

1225/0.06

1400/0.06

1575/0.07

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

46.7

42.8

40.2

39.4

47.1

43.2

40.2

40.1

47.2

43.3

40.2

40.8

SHC

24.3

30.7

31.3

37.3

25.1

32.5

32.8

39.6

25.7

33.9

34.4

40.8

kW

3.43

3.40

3.53

3.31

3.58

3.54

3.72

3.41

3.75

3.71

3.92

3.52

95

TC

45.1

41.0

38.1

37.4

45.4

41.5

38.2

38.7

45.4

41.5

38.1

39.7

SHC

23.7

29.9

30.1

36.1

24.5

31.8

31.8

38.7

25.2

33.3

33.2

39.7

kW

3.78

3.74

3.83

3.60

3.94

3.91

4.02

3.69

4.12

4.07

4.25

3.86

105

TC

43.5

38.8

35.9

35.6

43.5

39.2

35.9

36.8

43.5

39.4

35.8

37.9

SHC

23.3

28.7

29.1

35.4

23.9

30.6

30.6

36.8

24.7

32.3

32.0

37.9

kW

4.17

4.07

4.13

3.91

4.33

4.24

4.33

4.03

4.51

4.40

4.56

4.20

115

TC

41.0

36.6

33.8

34.0

41.2

36.9

33.8

35.2

41.3

36.9

33.7

35.9

SHC

22.1

27.9

28.3

34.0

23.0

29.6

29.8

35.2

23.7

31.1

31.3

35.9

kW

4.59

4.44

4.50

4.26

4.75

4.58

4.70

4.42

4.94

4.76

4.90

4.57

602A042 (3.5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

1225

TC

12.32

11.34

16.82

15.48

20.83

19.16

24.26

22.33

25.64

23.60

kW

2.38

2.50

2.61

2.68

2.71

1400

TC

13.56

12.47

17.91

16.48

21.69

19.96

25.15

23.14

26.50

24.38

kW

2.56

2.66

2.74

2.80

2.84

1575

TC

15.37

14.14

19.47

17.91

22.32

20.54

25.76

23.71

27.08

24.92

kW

2.71

2.80

2.89

2.91

2.96

70

1225

TC

10.27

9.45

15.14

13.93

19.86

18.27

23.10

21.25

24.51

22.55

kW

2.55

2.70

2.86

2.93

2.97

1400

TC

11.36

10.45

16.19

14.89

20.55

18.91

24.03

22.11

25.46

23.42

kW

2.72

2.85

2.99

3.06

3.08

1575

TC

11.80

10.85

16.48

15.17

21.17

19.47

24.68

22.70

26.09

24.00

kW

2.86

2.97

3.11

3.18

3.20

80

1225

TC

7.25

6.67

12.43

11.44

18.54

17.06

21.87

20.12

23.20

21.35

kW

2.73

2.90

3.10

3.22

3.25

1400

TC

8.50

7.82

13.58

12.49

18.39

16.92

22.84

21.02

24.21

22.27

kW

2.96

3.10

3.19

3.35

3.38

1575

TC

9.12

8.39

14.20

13.06

18.85

17.35

23.51

21.63

24.90

22.91

kW

3.09

3.21

3.34

3.47

3.49

602A042 (3.5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

1225

TC

30.15

27.74

36.33

36.33

38.87

38.87

39.69

39.69

42.11

42.11

kW

2.88

3.00

3.12

3.15

3.24

1400

TC

31.06

28.58

37.25

37.25

39.30

39.30

40.14

40.14

42.28

42.28

kW

3.00

3.12

3.18

3.21

3.28

1575

TC

31.68

29.15

37.83

37.83

39.73

39.73

40.47

40.47

42.54

42.54

kW

3.12

3.19

3.26

3.28

3.35

70

1225

TC

29.23

26.89

35.41

35.41

39.11

39.11

40.46

40.46

43.21

43.21

kW

3.10

3.24

3.46

3.49

3.62

1400

TC

30.16

27.75

36.46

36.46

40.08

40.08

41.02

41.02

43.67

43.67

kW

3.23

3.40

3.51

3.55

3.65

1575

TC

30.81

28.35

37.01

37.01

40.58

40.58

41.43

41.43

44.00

44.00

kW

3.34

3.42

3.59

3.63

3.72

80

1225

TC

28.04

25.80

34.82

34.82

38.24

38.24

39.84

39.84

43.96

43.96

kW

3.38

3.51

3.66

3.75

4.01

1400

TC

29.09

26.76

35.72

35.72

39.31

39.31

41.00

41.00

44.55

44.55

kW

3.49

3.61

3.81

3.86

4.03

1575

TC

29.79

27.41

36.41

36.41

39.95

39.95

41.72

41.72

45.08

45.08

kW

3.61

3.70

3.93

3.98

4.11

Advertising