SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROL

3-8

– JLG Lift –

3121219

Platform Control Front Panel

(Refer to Figure 3-3.)

1. Fuel/Glow Plug Selector Switch - Selects which fuel

source will be used. LPG vs. Gasoline or Diesel for die-
sel machines.

2. Auto Leveling Jacks - The leveling jacks switch is

located on the front of the platform control box. When
depressed, the outrigger light will illuminate on the indi-
cator pad. Moving the control handle forward will lower
the leveling jacks. Moving the control handle backward
will raise the leveling jacks. Once the machine is level,
the jacks will discontinue extending and the jack set
light will illuminate.

NOTE: After initial ground contact is made, the auto level function

will pause 2-5 seconds and then begin to properly level
the machine to the specified market specification. Once
level, the tilt light on the platform control box will stop
blinking.

NOTE: There is an override feature on the Auto Leveling system

that allows the operator to adjust (trim) the level of the
machine to the left or right when the platform is com-
pletely lowered. Use the following instructions to adjust
the level of the machine.

a. Select the leveling jack selection switch and

squeeze the red trigger switch on the controller.

b. To adjust the leveling jacks to the left, activate the

switch on top of the controller to the left. To adjust
to the right, activate the switch on top of the control-
ler to the right. The leveling jack indicator light for
the side selected will be lit.