Section 8 - Additional Checks

8-1

31200359

SECTION 8 - ADDITIONAL CHECKS

8.1

GENERAL

If any of the following test results cannot be achieved, the system is not
functioning properly and the machine must be removed from service and
repaired before continued operation.

8.2

LOAD STABILITY INDICATOR SYSTEM (2505)

A. Load Stability Indicator System Test

The Load Stability Indicator (LSI) is intended to continuously monitor the forward
stability of the telehandler. To check this feature, perform the following:

Before S/N 0160042694

1. Fully retract and level boom, with no load. Do not raise the boom during

this test.

2. Ensure machine is level.

3. Press the test button on the LSI display. This will cause all LEDs to flash on and

an audible warning to sound. This indicates that the system is functioning
properly.

S/N 0160042694 & After

1. Fully retract and level boom, with no load. Do not raise the boom during

this test.

2. Ensure machine is level.

3. Press the system check button on the LSI display. This will cause all LEDs to

flash on and an audible warning to sound. This indicates that the system is
functioning properly.

10