Load Stability Indicator - LSI (2505)

Before S/N 0160042694

The LSI (1) provides visual and audible indication of forward stability limitations
when machine is static on firm, level surface.

• Green LED (2) will illuminate when LSI power is on.

• When approaching forward stability limitations LEDs progressively illuminate,

green (3), then yellow (4) and finally red (5).

• The warning buzzer sounds as the first red LED illuminates.

• As the telehandler reaches its forward stability limitations and the second red

LED illuminates, the automatic function cut-out is activated. Certain functions are
disabled (i.e. boom lift, extend, etc). Retract boom to re-enable functions.

• Press button (6) to disable the warning buzzer. When disabled, yellow LED (7)

will illuminate. If last red LED illuminates, disable button is overridden and
warning buzzer sounds.

• Test LSI (8) at the beginning of each work shift. See Section 8 - Additional

Checks.

WARNING

TIP OVER HAZARD. The LSI considers only longitudinal stability limitations,
observe all operating parameters. Failure to follow operating parameters of the
telehandler could damage the equipment and/or cause tip over.