JLG 1250AJP Operator Manual User Manual
Page 110
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6-20
– JLG Lift –
3121170
C: Wheel Drive Hub - Reggiana Riduttori (S/N 134389 to Pres-
ent)
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o’clock position and Check
port at 3 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.
5.
Hydraulic Return Filter
(See Figure 6-7., Hydraulic Return Filter Condition Indicator - Prior to S/N
139396 and Figure 6-8., Hydraulic Return Filter Condition Indicator - S/N
139396 to Present)
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator.