JLG 1250AJP Operator Manual User Manual

Page 110

Advertising
background image

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-20

– JLG Lift –

3121170

C: Wheel Drive Hub - Reggiana Riduttori (S/N 134389 to Pres-

ent)

Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of

operation

Comments - Place Fill port at 12 o’clock position and Check

port at 3 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.

5.

Hydraulic Return Filter

(See Figure 6-7., Hydraulic Return Filter Condition Indicator - Prior to S/N
139396
and Figure 6-8., Hydraulic Return Filter Condition Indicator - S/N
139396 to Present)

Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator.

Advertising