SECTION 3 - MACHINE CONTROLS AND INDICATORS

3121170

– JLG Lift –

3-13

Platform Control Indicator Panel

(See Figure 3-3., Platform Control Indicator Panel)

1.

Level System Fault Indicator

Indicates a fault in the electronic leveling system. The fault
indicator will flash and an alarm sound. All functions will
default to creep if the boom is out of transport mode.

IF THE LEVEL SYSTEM FAULT INDICATOR IS ILLUMINATED, SHUT DOWN THE
MACHINE, RESET THE EMERGENCY STOP, AND RESTART THE MACHINE. IF THE FAULT
PERSISTS, RETURN THE PLATFORM TO THE STOWED POSITION, USING MANUAL LEV-
ELING AS REQUIRED, AND HAVE LEVELING SYSTEM REPAIRED.

2.

AC Generator (If Equipped)

Indicates the generator is in operation.

3.

Platform Overload Indicator (If Equipped)

Indicates the platform has been overloaded.

4.

Platform Capacity Indicator

Indicates the maximum platform capacity selected for the
platform.

One of the capacity lights should be on at all times. Both
lights will flash and an alarm will sound if the platform is out
of the operating envelope for the selected capacity.

5.

Tilt Alarm Warning Light

IF ILLUMINATED WHEN BOOM IS RAISED OR EXTENDED, RETRACT AND LOWER TO
BELOW HORIZONTAL THEN REPOSITION MACHINE SO THAT IT IS LEVEL BEFORE
EXTENDING BOOM OR RAISING BOOM FROM THE TRANSPORT POSITION.

Indicates that the chassis is on a slope (over 3 to 5 degrees,
depending upon boom angle). If the boom is out of trans-
port position and the machine is on a slope, an alarm will
sound and CREEP is automatically activated.