Pressure limiter valve replacement, 11 charge pump filter, Charge pump filter -31 – JLG 4394RT Service Manual User Manual

Page 196

Advertising
background image

SECTION 4 - HYDRAULICS

4-30

– JLG Lift –

3121249

Pressure Limiter Valve Replacement

NOTE: Replace the pressure limiter valve as a complete

unit. Do not attempt to repair individual components.

REMOVAL:

1. Using a 14 mm wrench, remove the pressure limiter

valves (L300/L400). Discard O-rings.

INSPECTION:

2. Inspect the sealing surfaces of the pump for nicks or

scratches.

REASSEMBY:

3. Install new O-ring. Lubricate 0-ring with petroleum

jelly.

4. Replace pressure limiter valves. Torque to 22 lb-ft

(30 Nm).

5. Operate pump at full range of controls to ensure

proper machine operation.

4.11 CHARGE PUMP FILTER

REMOVAL:

1. Disconnect and cap the hydraulic lines on the filter

(1).

2. Remove the four bolts (2) to remove the filter from

the bracket.

INSTALLATION:

1. Attach filter (1) to bracket using the four bolts (2).

2. Uncap and reconnect the hydraulic lines to the filter.

Pressure Limiter

14 mm
22 ft.lbs. 30 Nm

(

)

L300

L022

14 mm
22 ft.lbs. (30 Nm)

L400

1

2

1. Charge Pump Filter

2. Bolt, 3/8"-16NC x 5/8"20

Figure 4-26. Charge Pump Filter

Advertising