Flash code 2/2 indicates difficultly with the platform controls.

3

TRIGGER SWITCH WIRING SHORTED HIGH IN PLAT-
FORM CABLE

Reports when the CAN message coming from the platform board
and the DI on ground board conflict.

TRIGGER SWITCH WIRING SHORTED LOW IN PLAT-
FORM CABLE

Reports when the CAN message coming from the platform board
and the DI on ground board conflict.

FUNCTION LOCKED OUT – DRIVE SELECT PERMA-
NENTLY CLOSED

Reported when drive select is closed during power up.

FUNCTION LOCKED OUT – LIFT SELECT PERMA-
NENTLY CLOSED

Reported when lift select is closed during power up.

FUNCTION LOCKED OUT – FRONT DECK SELECT PER-
MANENTLY CLOSED

Reported when front deck select is closed during power up.

FUNCTION LOCKED OUT – REAR DECK SELECT PER-
MANENTLY CLOSED

Reported when rear deck select is closed during power up.

FUNCTION LOCKED OUT – START PERMANENTLY
CLOSED

Reported when the start switch is closed during power up.

FUNCTION LOCKED OUT – STEER LEFT PERMA-
NENTLY CLOSED

Reported when the left steer switch is closed during power up.

FUNCTION LOCKED OUT – STEER RIGHT PERMA-
NENTLY CLOSED

Reported when the right steer switch is closed during power up.

FUNCTION LOCKED OUT – AUX POWER SWITCH PER-
MANENTLY CLOSED

Reported when the auxiliary switch is closed during power up.

FUNCTION LOCKED OUT – GENERATOR SWITCH PER-
MANENTLY CLOSED

Reported when the generator switch is closed during power up.

FUNCTION LOCKED OUT – AUTOLEVEL SWITCH PER-
MANENTLY CLOSED

Reported when the leveling jack select switch is closed during
power up.

TRIGGER CLOSED TOO LONG WHILE IN NEUTRAL

Reported when trigger is closed for ten seconds and no function
selected.

FUNCTION LOCKED OUT – JOYSTICK NOT CENTERED Reported when joystick is not centered while selecting a function.
FUNCTION LOCKED OUT – TRIGGER SWITCH PERMA-
NENTLY CLOSED

Reported when the trigger switch is closed during power up.

JOYSTICK FAULTY – STEER SWITCHES ACTIVE
TOGETHER

Reported when both the left and right steer switches are closed at
the same time.

FUNCTION LOCKED OUT – HORN SWITCH PERMA-
NENTLY CLOSED

Reported when the horn switch is closed during power up.

JOYSTICK CALIBRATION FAULTY

Reported when joystick calibration is improper. (Platform P1.6 or
later only)

Table 5-2. Fault Code Listing - Software P1.X