SECTION 5 - JLG CONTROL SYSTEM

3121249

– JLG Lift –

5-13

2/6

Flash code 2/6 indicates leveling jack or power deck issues.

6

FRONT LEFT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the front
left leveling jack is open circuit.

FRONT LEFT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the front
left leveling jack is short to ground.

FRONT LEFT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the front
left leveling jack is short to battery.

FRONT RIGHT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the front
right leveling jack is open circuit.

FRONT RIGHT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the front
right leveling jack is short to ground.

FRONT RIGHT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the front
right leveling jack is short to battery.

REAR LEFT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the rear
left leveling jack is open circuit.

REAR LEFT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the rear
left leveling jack is short to ground.

REAR LEFT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the rear
left leveling jack is short to battery.

REAR RIGHT LEVELING JACK OPEN CIRCUIT

Reported by the I/O module and during system test when the rear
right leveling jack is open circuit.

REAR RIGHT LEVELING JACK SHORT TO GROUND

Reported by the I/O module and during system test when the rear
right leveling jack is short to ground.

REAR RIGHT LEVELING JACK SHORT TO BATTERY

Reported by the I/O module and during system test when the rear
right leveling jack is short to battery.

LEVELING JACK EXTEND VALVE OPEN CIRCUIT

Reported by the I/O module and during system test when the level-
ing jack extend valve is open circuit.

LEVELING JACK EXTEND VALVE SHORT TO GROUND

Reported by the I/O module and during system test when the level-
ing jack extend valve is short to ground.

LEVELING JACK EXTEND VALVE SHORT TO BATTERY

Reported by the I/O module and during system test when the level-
ing jack extend valve is short to battery.

LEVELING JACK RETRACT VALVE OPEN CIRCUIT

Reported by the I/O module and during system test when the level-
ing jack retract valve is open circuit.

LEVELING JACK RETRACT VALVE SHORT TO GROUND

Reported by the I/O module and during system test when the level-
ing jack retract valve is short to ground.

LEVELING JACK RETRACT VALVE SHORT TO BATTERY

Reported by the I/O module and during system test when the level-
ing jack retract valve is short to battery.

FRONT DECK EXTEND VALVE OPEN CIRCUIT

Reported by the I/O module and during system test when the front
deck extend valve is open circuit.

FRONT DECK EXTEND VALVE SHORT TO GROUND

Reported by the I/O module and during system test when the front
deck extend valve is short to ground.

FRONT DECK EXTEND VALVE SHORT TO BATTERY

Reported by the I/O module and during system test when the front
deck extend valve is short to battery.

FRONT DECK RETRACT VALVE OPEN CIRCUIT

Reported by the I/O module and during system test when the front
deck retract valve is open circuit.

Table 5-2. Fault Code Listing - Software P1.X

Fault Flash

Code

Communicated (Displayed on Analyzer) Fault

Description

Priority