SECTION 5 - JLG CONTROL SYSTEM

5-6

– JLG Lift–

3121249

5.2 CALIBRATIONS

Elevation Sensor Calibration

Using the Analyzer, in Access Level 1, go to MENU: CALI-
BRATION:

1. SET STOW ELEV;

a. Completely lower platform to stowed position.
b. Enter YES on the Analyzer.
c. COMPLETE will show on the analyzer when cali-

brated.

2. SET 26FT ELEV (3394RT) or SET 30FT ELEV

(4394RT);

a. Raise platform to a height of 26 feet for the

3394RT or 30 feet for the 4394RT (measured
deck to ground).

b. Enter YES on the Analyzer.
c. COMPLETE will show on the analyzer when cali-

brated.

3. SET 30FT ELEV (3394RT) or SET 36FT ELEV

(4394RT);

a. Raise platform to a height of 30 feet on the

3394RT or 36 feet for the 4394RT (measured
deck to ground).

b. Enter YES on the Analyzer.

c. COMPLETE will display on the analyzer when

calibrated.

NOTE: Elevation Proximity Switch must be mounted and

functioning properly to calibrate the Elevation Sen-
sor.

FOR MACHINE TO OPERATE TO CAPACITY, BE SURE TO CALI-
BRATE ELEVATION SENSOR AT ALL THREE POSITIONS.

1

2

3

1. Scissor Arm Assembly

2. Proximity Sensor

(on frame inboard slide channel)

3. Rotary Angle Sensor

Figure 5-3. Limit Switch Location