Starting the Engine

1. Make sure all controls are in “Neutral” and all electrical components (lights,

heater, defroster, etc.) are turned off. Set parking brake.

2. Depress accelerator pedal approximately 1/4 to 1/3 of travel from top.

3. Turn control station selector switch to cab, pull up emergency stop, and

push up on start/aux. switch to engage starting motor. If engine fails to

start within 20 seconds, release start/aux. switch and allow starting motor

to cool for a few minutes before trying again.

4. After engine starts, observe oil pressure gauge. If gauge remains on zero

for more than ten seconds, stop engine and determine cause. Correct

malfunction before restarting engine. Minimum pressure at operating
temperature:

Low idle: 10 PSI (69kPa)

5. Warm up engine at approximately 1/2 throttle until engine coolant

temperature reaches operating range.

Cold-Weather Starting Aids

In cold weather situations, a supplemental starting aid may be required. Gradall-

approved starting aids employ ether. If your handler is equipped with an ether

starting aid, the following applies:

• All employed ether is triggered by temperature gauge located on engine.

• At start-up, temperature gauge on engine will detect if ether is needed. Follow

normal start-up procedure, shown above.

• Ether is employed and additional will be released if needed, to keep engine

running.

• A second battery is added for additional cold-cranking capacity.

Battery-Boosted Starting

If you ever have to battery-boost start (jump-start) your handler, proceed as

follows:

• Never allow vehicles to touch

• Connect the positive (+) jumper cable to positive (+) post of discharged

battery

• Connect opposite end of positive (+) jumper cable to positive (+) post of

booster battery

• Connect the negative (-) jumper cable to negative (-) post on booster battery

• Connect opposite end of negative (-) jumper cable to ground point on machine

away from discharged battery

• Follow standard starting procedures

• Remove cables in reverse order after machine has started

ENGINE OPERATION

6.0

NOTE!

Engine will not start unless

transmission control lever is in
“Neutral” and parking brake

switch is applied.

WARNING

!

Operator must be seated with seat

belt fastened, transmission control
lever in “Neutral” position, parking

brake applied and all hydraulic

controls in “Neutral” before
starting engine.

CAUTION

!

If your machine is equipped with

a cold start aid, do not spray
additional ether into air cleaner.

If machine is not equipped with
cold start aid, follow instructions

listed in the engine manual

supplied with machine.