4.3 BATTERY CHARGING & MAINTENANCE

AMI Models are equipped with a 12 volt, 10 amp output - dual
voltage (120/240V) input battery charger. The charger is micro-
processor controlled featuring an automatic charge sensing cir-
cuit which can determine cell voltage and regulate charger
output and terminate charging as required.

Battery Maintenance and Safety

(See Figure 4-1.

)

• BATTERY ACID IS HIGHLY CORROSIVE. AVOID CONTACT

WITH SKIN AND CLOTHING AT ALL TIMES.

• BATTERY ACID RELEASES AN EXPLOSIVE GAS WHILE

CHARGING, ALLOW NO OPEN FLAMES, SPARKS OR
LIGHTED TOBACCO PRODUCTS IN THE AREA WHILE
CHARGING BATTERIES. CHARGE BATTERIES ONLY IN A
WELL VENTILATED AREA.

• ADD ONLY DISTILLED WATER TO BATTERIES. WHEN

ADDING DISTILLED WATER TO THE BATTERIES, A NON-
METALLIC CONTAINER AND/OR FUNNEL MUST BE
USED.

The battery fluid level should be approximately 1/8" (3mm)
below vent tubes. (See Figure 4-1.)

Figure 4-1. Battery Fluid Level.

1. Battery Filler Cap
2. Vent Tube

3. Fluid Level
4. Cell Plates

1/8 "

(3mm)

1

3

2

4